Intellio C218Turbo/PCI User’s Manual
A High Performance 8 Port Async Board for PCI Bus
March. 1999 (3rd Edition)
The content of this manual is also available in CD-ROM and at Moxa Web Site.
Moxa Technologies Co., Ltd.
Tel: +866-2-8665-6373
Fax: +886-2-8665-6372
www.moxa.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 92 93

Shrnutí obsahu

Strany 1 - March. 1999 (3rd Edition)

Intellio C218Turbo/PCI User’s ManualA High Performance 8 Port Async Board for PCI BusMarch. 1999 (3rd Edition)The content of this manual is also avail

Strany 2 - Disclaimer

1-4 Intellio C218Turbo /PCI User's Manualv Device driver diskettes:l Windows NT and Windows 95/98 ¡Ñ1l PComm Lite ¡Ñ1l UNIX ¡Ñ1v Intel

Strany 3 - MOXA Internet Services

IntroductionIntellio C218Turbo /PCI User's Manual 1-5Installation GuideThis section gives a brief summary of how to install the Intellio C218T

Strany 4 - About This Manual

1-6 Intellio C218Turbo /PCI User's Manual

Strany 5 - Table of Contents

Intellio C218Turbo /PCI User's Manual 2-122 2 Hardware InstallationThe installation of Intellio C218Turbo/PCI consists of hardware installati

Strany 6

2-2 Intellio C218Turbo /PCI User's ManualStep 7: Connect one of the connection box/cable (also adapter if required) detailedin the next Sectio

Strany 7 - 1 Introduction

Hardware InstallationIntellio C218Turbo /PCI User's Manual 2-312345678TxRx Opt8A/Opt8B/Opt8SIntellio C218Turbo/PCIOpt8C/Opt8DHold one end of

Strany 8

2-4 Intellio C218Turbo /PCI User's Manual12345678TxRxOpt8F/Opt8Z/Opt8JIntellio C218 Turbo/PCIIf you can't make the Intellio C218Turbo/PCI

Strany 9 - Check List

Hardware InstallationIntellio C218Turbo /PCI User's Manual 2-5RS-422 ModeSet the respective switch to OFF position to use RS-422 interface. Th

Strany 10 - Opt8F/Opt8Z

2-6 Intellio C218Turbo /PCI User's Manual

Strany 11 - Installation Guide

Intellio C218Turbo /PCI User's Manual 3-133 3 Software InstallationIn this chapter, software driver installation, configuration and d

Strany 12

Intellio C218Turbo/PCI User’s ManualThe software described in this manual is furnished under a license agreement and may be used only inaccordance wit

Strany 13 - 2 Hardware Installation

3-2 Intellio C218Turbo /PCI User's ManualInstalling DriverThe following is the procedure for installing the Intellio C218Turbo/PCI driver fort

Strany 14

Software InstallationIntellio C218Turbo /PCI User's Manual 3-35. Select “MOXA Intellio C218Turbo Multiport Board” in the “Select OEMOption” d

Strany 15 - Opt8J/Opt8F/Opt8Z

3-4 Intellio C218Turbo /PCI User's ManualYou have to set up all the ports of the board with the desired “COM number”,which should not conflict

Strany 16 - Operating Opt8J

Software InstallationIntellio C218Turbo /PCI User's Manual 3-5In the “Advanced Settings” dialog, you may customize the driver with

Strany 17 - RS-485 Mode

3-6 Intellio C218Turbo /PCI User's Manual8. Click [OK] in the “Individual Port Setting” and the “Property” dialog boxes togo back to the “MOXA

Strany 18

Software InstallationIntellio C218Turbo /PCI User's Manual 3-7l Enter [Administrative] group, then open [Event Viewer] icon and then select[A

Strany 19 - 3 Software Installation

3-8 Intellio C218Turbo /PCI User's Manual3. Click on [Properties…] button to start the “MOXA Configuration Panel”dialog.In this conf

Strany 20 - Installing Driver

Software InstallationIntellio C218Turbo /PCI User's Manual 3-9l Click [Add] to add one more board that is not yet configured in the system.Up

Strany 21 - Software Installation

3-10 Intellio C218Turbo /PCI User's ManualRemoving DriverTo remove the driver for the Intellio C218Turbo/PCI board,1. Open the [Control Panel]

Strany 22

Software InstallationIntellio C218Turbo /PCI User's Manual 3-11Installing DriverIf you are the first time installer or you want to install mor

Strany 23

MOXA Internet ServicesCustomer’s satisfaction is always our number one concern. To ensure that customers get the full benefitof our services, Moxa Int

Strany 24

3-12 Intellio C218Turbo /PCI User's ManualThe following flow chart illustrates the driver installation stages of the IntellioC218Tu

Strany 25 - Configuring Board and Port

Software InstallationIntellio C218Turbo /PCI User's Manual 3-13First Time Driver Installation StageThe stage presents the steps for installing

Strany 26

3-14 Intellio C218Turbo /PCI User's Manual3. Type “A:\Windows.95” in the Location field,and click [OK]. The system will start readingthe files

Strany 27 - Updating Driver

Software InstallationIntellio C218Turbo /PCI User's Manual 3-156. Click [Next>].7. Click [Next>].

Strany 28 - Windows 95/98

3-16 Intellio C218Turbo /PCI User's ManualPort Configuration StageThis stage displays the “MOXA Ports Installation” dialog box for the portcon

Strany 29

Software InstallationIntellio C218Turbo /PCI User's Manual 3-17Board and Port Ready StageClick on [OK] buttons for all the dialog boxes to fin

Strany 30

3-18 Intellio C218Turbo /PCI User's ManualOnce the installation is finished, error conditions of the board, if any, are displayedon the screen

Strany 31 - 3-13

Software InstallationIntellio C218Turbo /PCI User's Manual 3-19Configuring Board and PortIf you already have installed the driver and

Strany 32

3-20 Intellio C218Turbo /PCI User's Manual3. In the “Property” dialog, you may click on [Port Setting] button to enter thefollowing “Individua

Strany 33 - 3-15

Software InstallationIntellio C218Turbo /PCI User's Manual 3-21In the “Individual Port Setting” dialog box, you may have two ways to map t

Strany 34 - Port Configuration Stage

About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog

Strany 35 - Board and Port Ready Stage

3-22 Intellio C218Turbo /PCI User's ManualIn the “Advanced Settings” dialog box, you may customize the driver with thefollowing tw

Strany 36

Software InstallationIntellio C218Turbo /PCI User's Manual 3-23Updating driverOpen the [Control Panel] and click on the [System] button, and s

Strany 37

3-24 Intellio C218Turbo /PCI User's ManualUNIXThere are various UNIX operating systems, such as SCO UNIX, UNIX SVR4.2,XENIX and Solaris, et

Strany 38

Software InstallationIntellio C218Turbo /PCI User's Manual 3-25MOXA UNIX Device Driver Installation Ver. x.xPlease select one of the following

Strany 39 - 3-21

3-26 Intellio C218Turbo /PCI User's ManualFor more details, see later section “Administration Utility -mxadm”. Up to now, you have already com

Strany 40

Software InstallationIntellio C218Turbo /PCI User's Manual 3-27MOXA TTY Device Naming ConventionIf the Intellio C218Turbo/PCI is successfully

Strany 41 - Removing driver

3-28 Intellio C218Turbo /PCI User's ManualAdministration Utility - mxadmYou can use the administration utility, mxadm, to change the

Strany 42

Software InstallationIntellio C218Turbo /PCI User's Manual 3-29In the “Basic Configuration” dialog, you should first press Enter in board type

Strany 43 - 3-25

3-30 Intellio C218Turbo /PCI User's ManualAdvanced ConfigurationThis is to provide advanced settings for advanced driver features be

Strany 44

Software InstallationIntellio C218Turbo /PCI User's Manual 3-312. Press PageDown to enter “Advanced Port Settings” sub-dialog, there are somen

Strany 45

Table of ContentsIntroduction...1-1Overview ...

Strany 46 - Basic Configuration

3-32 Intellio C218Turbo /PCI User's ManualResponseThree levels, Slow, Normal and Fast, of port response time are designed foruser's n

Strany 47 - Non-Modem and Modem Baud Rate

Software InstallationIntellio C218Turbo /PCI User's Manual 3-33Performance TuningThe utility let you tune the favored response time for those

Strany 48 - Baud Rate Mapping

3-34 Intellio C218Turbo /PCI User's ManualHowever, before the board reset is issued, you must make sure that1. All enabled ports must be disab

Strany 49 - 3-31

Software InstallationIntellio C218Turbo /PCI User's Manual 3-35Checking Board Initialization StatusWhen the system starts up and enters into t

Strany 50 - RTS/CTS Hardware Flow Control

3-36 Intellio C218Turbo /PCI User's Manual

Strany 51 - Board Reset

Intellio C218Turbo /PCI User's Manual 4-144 4 Serial Programming ToolsMoxa supports powerful but easy serial programming library and

Strany 52 - Driver Removal

4-2 Intellio C218Turbo /PCI User's ManualPComm Programming LibraryThe serial communication library is to assist users to develop programs for

Strany 53 - 3-35

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-3Diagnostic (for MOXA boards only)A co3nvenient diagnostic program provides in

Strany 54

4-4 Intellio C218Turbo /PCI User's ManualMonitor (for MOXA boards under Windows NT Only)A useful port status monitoring program allows you to

Strany 55 - 4 Serial Programming Tools

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-5Terminal EmulatorThe Terminal Emulator features multi-windows and suppo

Strany 56 - Utilities

Extended UNIX Ioctl() Commands... ... ...4-6Utilities ...

Strany 57 - Serial Programming Tools

4-6 Intellio C218Turbo /PCI User's ManualUNIXProgramming the MOXA PortsThe system calls that apply to standard tty port can also be applied to

Strany 58

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-7Syntax for SCO UNIX/XENIX#define MIBUFED 0x401int count; /* number of bytes q

Strany 59 - Terminal Emulator

4-8 Intellio C218Turbo /PCI User's Manualioc.ic_cmd = MOBUFED;ioc.ic_timout = 0;ioc.ic_len = sizeof(int);ioc.ic_dp = (char *)&count;ioctl(

Strany 60 - Programming the MOXA Ports

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-9Syntax for SCO UNIX/XENIX#define MTCDTR 0x404#define TurnON 1#define TurnOFF

Strany 61 - 2. MOBUFED

4-10 Intellio C218Turbo /PCI User's ManualSyntax for SCO UNIX/XENIX#define MLOWATER 0x405int lowater; /* low water value of output buffer (de

Strany 62 - 4. MTCDTR

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-117. MHWFLOWThis function is used to enable/disable hardware flow control. The

Strany 63 - 5. MLOWATER

4-12 Intellio C218Turbo /PCI User's ManualUtilitiesYou can use the administration utility, mxadm, to monitor port activity and to doterminal e

Strany 64 - 6. MSTATUS

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-13Terminal EmulatorThis utility provides data sending and receiving ability

Strany 65 - 7. MHWFLOW

4-14 Intellio C218Turbo /PCI User's Manual2 Select and enter “Terminal” to enter terminal emulation. Or select and enter“Advanced Transfer Mod

Strany 66

Serial Programming ToolsIntellio C218Turbo /PCI User's Manual 4-15RS-485 Programming for Opt8JIf you intend to do RS-485 communication with Op

Strany 67 - 4-13

Intellio C218Turbo /PCI User's Manual 1-111 1 IntroductionOverviewIntellio - The Intelligent Multiport Serial I/O SolutionsThe Intellio C21

Strany 68

4-16 Intellio C218Turbo /PCI User's ManualSolution 2There's a dedicated RS-485 function in PComm library. It integrates the abovefunction

Strany 69 - RS-485 Programming for Opt8J

Intellio C218Turbo /PCI User's Manual 5-155 5 Connection Option (Opt8x) and Cable WiringIn serial data communications, the term DTE is for Da

Strany 70

5-2 Intellio C218Turbo /PCI User's ManualThe followings are pin assignments for various connection options:Opt8A/S(DCE, DB25 Female)2 RxD3 TxD

Strany 71

Connection Option (Opt8x) and Cable WiringIntellio C218Turbo /PCI User's Manual 5-3Type 1: To connect Intellio C218Turbo/PCI to a DTE device.P

Strany 72

5-4 Intellio C218Turbo /PCI User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt8DOpt8D DTE DeviceDB9 Male DB25 MaleRxD 2

Strany 73 - Opt8B/C DTE Device

Connection Option (Opt8x) and Cable WiringIntellio C218Turbo /PCI User's Manual 5-5Modem,or any DCE DeviceOpt8B/CStraight-through CableOpt8B/C

Strany 74 - Opt8A/S DCE Device

5-6 Intellio C218Turbo /PCI User's ManualType 3: To connect Intellio C218Turbo/PCI to a DTE with 3-pin wiring.If the “Hardware flow control” f

Strany 75 - Opt8D DCE Device

Connection Option (Opt8x) and Cable WiringIntellio C218Turbo /PCI User's Manual 5-7PC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt

Strany 76

5-8 Intellio C218Turbo /PCI User's ManualRS-422 Cable Wiring for Opt8J/F/ZRS-422 connection boxes designed for Intellio C218Turbo/PCI are:Opt8

Strany 77 - Terminal, or any DTE Device

Connection Option (Opt8x) and Cable WiringIntellio C218Turbo /PCI User's Manual 5-9The followings are operation modes for RS-422:RS-422 Point-

Strany 78

1-2 Intellio C218Turbo /PCI User's ManualASIC Design, Compact SizeThe Intellio C218Turbo/PCI is also equipped with MOXA customer-designed ASIC

Strany 79

5-10 Intellio C218Turbo /PCI User's ManualRS-485 Cable Wiring for Opt8JOne RS-485 connection box designed for Intellio C218Turbo/PCI is:Opt8J:

Strany 80 - RS-485 Cable Wiring for Opt8J

Connection Option (Opt8x) and Cable WiringIntellio C218Turbo /PCI User's Manual 5-11RS-422/485 Impedance MatchingFor RS-422/485 serial communi

Strany 81 - RS-422/485 Impedance Matching

5-12 Intellio C218Turbo /PCI User's Manual

Strany 82

Intellio C218Turbo /PCI User's Manual 6-166 6 TroubleshootingCommon C218 Turbo/PCI problems and possible solutions are listed below,

Strany 83 - 6 Troubleshooting

6-2 Intellio C218Turbo /PCI User's Manualreport of diagnostics shows error, replace the error component.Software Causes and Solutions:a. Intel

Strany 84 - Windows NT

TroubleshootingIntellio C218Turbo /PCI User's Manual 6-33. Windows NT system panic (blue screen).The possible reason is IRQ or memory conflict

Strany 85

6-4 Intellio C218Turbo /PCI User's ManualUNIXThis section is specific for troubleshooting under UNIX. For general problems andsolutions, pleas

Strany 86

TroubleshootingIntellio C218Turbo /PCI User's Manual 6-55. The newly rebuilt kernel could not boot.The C218 Turbo/PCI driver might not be buil

Strany 87 - Troubleshooting

6-6 Intellio C218Turbo /PCI User's Manual

Strany 88

Intellio C218Turbo /PCI User's Manual A-1AAppppeennddiixx A Technical ReferenceSpecificationsv Bus interface: 32-bit PCI (PCI Spec. 2.1 comp

Strany 89 - Technical Reference

IntroductionIntellio C218Turbo /PCI User's Manual 1-3l PC-based (vending) Machine or Kiosk SystemPoint-of-Sale (POS) SystemFeaturesThe follo

Strany 90 - Dual-Ported RAM

A-2 Intellio C218Turbo /PCI User's ManualC218Turbo/PCIWindows NT3Windows 95/98 3SCO UNIX/OpenServer 3UNIX SVR4.2 3XENIX 33: Driver supported b

Strany 91 - DB62 Connector Pinouts

Technical ReferenceIntellio C218Turbo /PCI User's Manual A-3faster than normal I/O access.All messages and data are transferred through this

Strany 92 - Problem Report Form

Problem Report FormIntellio C218Turbo/PCI Customer name: Company: Tel: Fax: Email: Date:1. Moxa Product: C218Turbo/PCI Serial Number: ________

Strany 93 - Return Procedure

Return ProcedureFor product repair, exchange or refund, you must:v Provide evidence of original purchase v Fill out the Problem Report Form (PRF) as

Komentáře k této Příručce

Žádné komentáře