EDS-600 Series User’s Manual Featured Functions
3-91
NOTE
The following events will be recorded into the EDS-600’s Event Log table:
1. Cold start
2. Warm start
3. Configuration change activated
4. Power 1/2 transition (Off Æ On), Power 1/2 transition (On Æ Off)
5. Authentication fail
6. Topology changed
7. Master setting is mismatched
8. DI 1/2 transition (Off Æ On), DI 1/2 transition (On Æ Off)
9. Port traffic overload
10. dot1x Auth Fail
11. Port link off / on
Using Syslog
This function provides the event logs for the syslog server. The function supports 3 configurable
syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent
as a syslog UDP packet to the specified syslog servers.
Syslog Server 1
Setting Description Factory Default
IP Address Enter the IP address of 1st Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 1st Syslog Server. 514
Syslog Server 2
Setting Description Factory Default
IP Address Enter the IP address of 2nd Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 2nd Syslog Server. 514