WE-2100T Series User’s Manual Serial Command Mode
13-3
For example, to indicate that the TCP server port number has been written successfully, the
module would return "<YTL" followed by CR. Available OP codes and parameters are described
in the next section.
Command Set
Basic Commands
OP Code Parameter Comments
BS (read only) serial number
BV (read only) firmware version
BN (alphanumeric, max. 15 bytes) server name
BW
0: disable
1: enable
web console
BT
0: disable
1: enable
Telnet console
BP (alphanumeric, max. 10 bytes) password
BR
1: restart only
2: save & restart (write only)
save and restart
NC
0: static
1: DHCP
IP configuration
NP
xxx.xxx.xxx.xxx
(e.g., 192.168.127.254)
IP address
NM
xxx.xxx.xxx.xxx
(e.g., 255.255.0.0)
netmask
NG
xxx.xxx.xxx.xxx
(e.g., 192.168.1.254)
gateway
NA
(read only)
(e.g., 00:90:e8:09:44:fe)
MAC address
Accessible IP Commands
OP Code Parameter Comments
AS
0: disable
1: enable
accessible IP list filtering
AA
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 01
AB
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 02
AC
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 03
AD
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 04
AE
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 05
AF
xxx.xxx.xxx.xxx
(e.g., 192.168.127.1)
accessible IP address 06
Zobrazit stránku 137