PCI Express Board User’s Manual Software Installation
3-42
Tx FIFO Rx FIFO
High 128 120
Middle 64 60
Low 1 1
Unit: Bytes
9. If you use the CP-114EL, CP-114EL-I, CP-132EL, CP-132EL-I, select Interface (RS-232,
RS-422, 2-wire RS-485, 4-wire RS-485) and Termination Resistor (120, Enable or Disable)
to configure. Take the CP-114EL for example. If you would like to configure as RS-422 and
no Termination Resistor, please see figures below. However, if you use the CP-118EL, please
refer to Chapter 2 to configure interface by DIP switch and Termination Resistor by jumper.
10. Click OK to save the port settings, and then click OK in the Property window to finish the
port settings procedure.