Moxa Technologies NPort 5200 Serie Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery Moxa Technologies NPort 5200 Serie. Moxa Technologies NPort 5200 Serie User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 259
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User’s Manual

CN2610 Dual-LAN Async Server User’s Manual Third Edition, June 2006 www.moxa.com/product MOXA Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886

Strany 2 - Disclaimer

CN2610 User’s Manual Introduction 1-3Front Panel RxTx12345678910111213141516ResetReadySELMENUCN261016 port RS-232 Async ServerLCM Display PanelReset

Strany 3 - Table of Contents

CN2610 User’s Manual Setting Up Device Control 5-11ASPP Examples for Windows 1. Program testing environment: RS-232CN2610EthernetTerminalWindows PC

Strany 4

66 Chapter 6 Setting Up Raw UDP UDP is a non connection-oriented data transmission method. By circumventing TCP’s handshaking process, UDP gains t

Strany 5

CN2610 User’s Manual Setting Up Raw UDP 6-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility by Te

Strany 6

CN2610 User’s Manual Setting Up Raw UDP 6-3Selecting the Application Open Port Menu Æ Mode to configure the Raw UDP application. 1. From the MAIN M

Strany 7

CN2610 User’s Manual Setting Up Raw UDP 6-45. The only operation mode associated with this application is RAW UDP, which is selected automatically

Strany 8 - Introduction

CN2610 User’s Manual Setting Up Raw UDP 6-5Setting Value Notes NecessityDest. IP address 1/2/3/4 Begin: x.x.x.x End: y.y.y.y Port: 1 to 65535 Def

Strany 9 - Package Checklist

CN2610 User’s Manual Setting Up Raw UDP 6-6CN2610-8 CN2610-8_19 V2.0 MAIN MENU -------------------

Strany 10 - Bottom Label

CN2610 User’s Manual Setting Up Raw UDP 6-7CN2610-8 CN2610-8_19 V2.0 SERVER MENU -------------------

Strany 11 - Getting Started

77 Chapter 7 Setting Up the Dual-host Redundant Data Acquisition System This chapter includes information about how to set up a CN2610 Async Serve

Strany 12 - Hardware Installation

CN2610 User’s Manual Setting Up DRDAS 7-2Configuring Port Operation Mode – Port Menu [Mode] Open Port MenuÆMode to install DRDAS mode and applicatio

Strany 13 - Connecting to the Network

22 Chapter 2 Getting Started This chapter includes instructions on where and how to install CN2610 Dual LAN Async Server. Both basic and advanced

Strany 14 - Configuration Checklist

CN2610 User’s Manual Setting Up DRDAS 7-3CN2610-8 CN2610-8_19 V2.0 MAIN MENU--------------------

Strany 15

CN2610 User’s Manual Setting Up DRDAS 7-4CN2610-8 CN2610-8_19 V2.0 -----------------------------

Strany 16 - Using Telnet

CN2610 User’s Manual Setting Up DRDAS 7-5+-----------------------------------------------------+| TCP data port : [955] || TCP command

Strany 17 - 2. Click Next to Continue

CN2610 User’s Manual Setting Up DRDAS 7-63. Specify the relevant settings. CN2610-8 CN2610-8_19 V2.0

Strany 18 - 5. Click Next to continue

CN2610 User’s Manual Setting Up DRDAS 7-7CN2610-8 CN2610-8_19 V2.0 -----------------------------

Strany 19 - 7. Click Close

CN2610 User’s Manual Setting Up DRDAS 7-8CN2610-8 CN2610-8_19 V2.0 -------------------------

Strany 20

88 Chapter 8 Setting Up Reverse Terminal In this chapter, we show how to use CN2610 to connect terminals to a computer over an Ethernet network. T

Strany 21

CN2610 User’s Manual Setting Up Reverse Terminal 8-2Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utili

Strany 22 - Server Configuration—Info

CN2610 User’s Manual Setting Up Reverse Terminal 8-3Selecting the Application Open Port Menu Æ Mode to configure the Reverse Terminal application. 1

Strany 23

CN2610 User’s Manual Setting Up Reverse Terminal 8-45. The only operation mode associated with this application is Reverse Terminal mode, which is

Strany 24 - Server Configuration—LAN

CN2610 User’s Manual Getting Started 2-2Hardware Installation Desktop Place your CN2610 on a clean, flat, well-ventilated desktop. For better ventil

Strany 25 - Server Configuration—Adv

CN2610 User’s Manual Setting Up Reverse Terminal 8-5Setting Value Notes NecessityTCP port number Each of CN2610’s serial ports is mapped to a T

Strany 26

CN2610 User’s Manual Setting Up Reverse Terminal 8-6CN2610-8 CN2610-8_19 V2.0 PORT MENU ----------

Strany 27

CN2610 User’s Manual Setting Up Reverse Terminal 8-7Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN261

Strany 28

99 Chapter 9 Setting Up Terminal In this chapter, we describe the steps you should follow to configure Moxa CN2610 as a Terminal Server. CN2610 pr

Strany 29

CN2610 User’s Manual Setting Up Terminal 9-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility by T

Strany 30

CN2610 User’s Manual Setting Up Terminal 9-3Selecting the Application Open Port Menu Æ Mode to configure the Terminal application. 1. From the MAIN

Strany 31 - Knowing Your Application

CN2610 User’s Manual Setting Up Terminal 9-45. TERM_ASC mode is selected by default. CN2610-8 CN2610-8_19 V2.0

Strany 32 - 9 10111213141516

CN2610 User’s Manual Setting Up Terminal 9-53. Move the cursor to the Description/more setting column and press Enter. CN2610-8

Strany 33

CN2610 User’s Manual Setting Up Terminal 9-6Setting Value Notes Necessity Telnet TCP port 23 Enter a number or leave the space blank. If not sp

Strany 34

CN2610 User’s Manual Setting Up Terminal 9-71. Move the cursor to the Mode column for the port and press Enter. CN2610-8 CN

Strany 35 - UDP datagram

CN2610 User’s Manual Getting Started 2-3Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or w

Strany 36

CN2610 User’s Manual Setting Up Terminal 9-8+------------------------------------------------+| Quit key : [^E] || Auto-link protocol :

Strany 37

CN2610 User’s Manual Setting Up Terminal 9-9Setting Value Notes Necessity Authentication type None/local/ server None: Authentication is not req

Strany 38

CN2610 User’s Manual Setting Up Terminal 9-10Setting Value Notes Speed 50 bps to 921.6 Kbps Transmission rate Bits 5, 6, 7, 8 Data bits Stop

Strany 39 - Terminal Access (Terminal)

CN2610 User’s Manual Setting Up Terminal 9-11Restart 1. From the MAIN MENU, select Restart. CN2610-8 CN2610-8_19 V2.0

Strany 40

1100 Chapter 10 Setting Up Multi-host TTY The Multi-host TTY application is the ideal transmission method for communicating with multiple Unix hos

Strany 41

CN2610 User’s Manual Setting Up Multi-Host TTY 10-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utili

Strany 42

CN2610 User’s Manual Setting Up Multi-Host TTY 10-3Selecting the Application Open Port Menu Æ Mode to configure the Multi-host TTY application. 1.

Strany 43

CN2610 User’s Manual Setting Up Multi-Host TTY 10-45. The only operation mode associated with this application is FIXTTY mode, which is selected au

Strany 44 - Real TTY/Unix Fixed TTY

CN2610 User’s Manual Setting Up Multi-Host TTY 10-5Setting Value Notes NecessityMax. Sessions 1-8 Select the maximum number of simultaneous ses

Strany 45

CN2610 User’s Manual Setting Up Multi-Host TTY 10-6CN2610-8 CN2610-8_19 V2.0 -------------------

Strany 46

CN2610 User’s Manual Getting Started 2-4Connecting to a Serial Device Use appropriately wired serial data cables to connect serial devices to CN2610

Strany 47 - Configuring ASPP Mode

CN2610 User’s Manual Setting Up Multi-Host TTY 10-7CN2610-8 CN2610-8_19 V2.0 MAIN MENU -----------

Strany 48

CN2610 User’s Manual Setting Up Multi-Host TTY 10-84. Compile and link documents: SCO OpenServer : # make sco SCO UnixWare : # make svr5 Uni

Strany 49

CN2610 User’s Manual Setting Up Multi-Host TTY 10-9Transparent Printer Access It’s not necessary to add additional entries to /etc/inittab for print

Strany 50

1111 Chapter 11 Setting Up Dialin/out In this chapter, we describe the steps required to configure Moxa CN2610 as a Dial-in/out Access Server. Dia

Strany 51

CN2610 User’s Manual Setting Up Dial-in/Out 11-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility

Strany 52

CN2610 User’s Manual Setting Up Dial-in/Out 11-3Selecting the Application Open Port Menu Æ Mode to configure the Dial-up/out application. 1. From t

Strany 53

CN2610 User’s Manual Setting Up Dial-in/Out 11-4CN2610-8 CN2610-8_19 V2.0 ----------------------

Strany 54

CN2610 User’s Manual Setting Up Dial-in/Out 11-5CN2610-8 CN2610-8_19 V2.0 ----------------------

Strany 55

CN2610 User’s Manual Setting Up Dial-in/Out 11-6Setting Value Notes NecessityIncoming PAP check None/local/server None: Authentication is not r

Strany 56

CN2610 User’s Manual Setting Up Dial-in/Out 11-7CN2610-8 CN2610-8_19 V2.0 ----------------------

Strany 57

CN2610 User’s Manual Getting Started 2-5to complete the configuration process and to gather information about all servers on the network. 1. Run up

Strany 58 - Installing Ports

CN2610 User’s Manual Setting Up Dial-in/Out 11-8Setting Value Notes NecessityIncoming PAP check None/local/server None: Authentication is not r

Strany 59

CN2610 User’s Manual Setting Up Dial-in/Out 11-9CN2610-8 CN2610-8_19 V2.0 ----------------------

Strany 60

CN2610 User’s Manual Setting Up Dial-in/Out 11-10+------------------------------------------------+| Quit key : [^E] || Auto-link protoc

Strany 61

CN2610 User’s Manual Setting Up Dial-in/Out 11-11Setting Value Notes Necessity Authentication type None/local/ server None: Authentication is no

Strany 62

CN2610 User’s Manual Setting Up Dial-in/Out 11-12Setting Value Notes NecessityInactivity time 0-99 minutes Idle time before the port is disconn

Strany 63

CN2610 User’s Manual Setting Up Dial-in/Out 11-13Configuring the Serial Ports Open Port Menu Æ Line to configure serial port settings. 1. From the

Strany 64

CN2610 User’s Manual Setting Up Dial-in/Out 11-144. Press ESC to return to the PORT MENU. Configuring Modem Initialization Open Port Menu Æ Modem t

Strany 65

CN2610 User’s Manual Setting Up Dial-in/Out 11-15Optional Welcome Message Open Port Menu Æ Welcome_MSG to set up a welcome message to greet dial-in

Strany 66 - Installing a Server

CN2610 User’s Manual Setting Up Dial-in/Out 11-16CN2610-8 CN2610-8_19 V2.0 -----------------------

Strany 67 - Next to continue

CN2610 User’s Manual Setting Up Dial-in/Out 11-17Restart 1. From the MAIN MENU, select Restart. CN2610-8 CN2610-8_19 V2.0

Strany 68

CN2610 User’s Manual Getting Started 2-6connections, and then use search to try locating the server again. Using Telnet 1. Telnet over the netwo

Strany 69

1122 Chapter 12 Setting Up Printer In this chapter, we describe how to set up Moxa CN2610 as a printer server. Up to 16 serial printers can be con

Strany 70

CN2610 User’s Manual Setting Up Printer 12-2Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility by Te

Strany 71

CN2610 User’s Manual Setting Up Printer 12-3Selecting the Application Open Port Menu Æ Mode to set up the Printer application. 1. From the MAIN MEN

Strany 72

CN2610 User’s Manual Setting Up Printer 12-45. The Dialin/out application supports two operation modes: RAW PRN and LPD PRN. RAW PRN mode is select

Strany 73

CN2610 User’s Manual Setting Up Printer 12-5CN2610-8 CN2610-8_19 V2.0 --------------------------

Strany 74

CN2610 User’s Manual Setting Up Printer 12-6Configuring LPD PRN Mode 1. Move the cursor to the Mode column for the port and then press Enter. CN261

Strany 75

CN2610 User’s Manual Setting Up Printer 12-7Setting Value Notes NecessityQueue name (RAW) Text Specify print queue’s name (in RAW mode) Fixed

Strany 76

CN2610 User’s Manual Setting Up Printer 12-8Parity None, Even, Odd, Mark, Space Odd, Even, Mark, Space FIFO Yes, No First In First Out Device RT

Strany 77

CN2610 User’s Manual Setting Up Printer 12-9Restart 1. From the MAIN MENU, select Restart. CN2610-8 CN2610-8_19 V2.0

Strany 78

CN2610 User’s Manual Setting Up Printer 12-10Steps SCO UNIX Command Description set rw #chmod 600 /dev/iop1 Change access permission to 600 or rw

Strany 79 - Setting

CN2610 User’s Manual Getting Started 2-7 2. Click Next to Continue. 3. Select the I Agree option and then click Next.

Strany 80

CN2610 User’s Manual Setting Up Printer 12-11Steps SCO UNIX Command Description execute asprint for Group 01 #/asprint /dev/iop1 ‘CN2610 IP addres

Strany 81

CN2610 User’s Manual Setting Up Printer 12-12Steps SCO UNIX Command Description execute asprint for Group 01 #/asprint /dev/iop1 ‘CN2610 IP addres

Strany 82

CN2610 User’s Manual Setting Up Printer 12-133. Select Microsoft TCP/IP Printing, and then click OK to continue. 4. Insert the Windows NT install

Strany 83

CN2610 User’s Manual Setting Up Printer 12-14 10. In the window that opens next, click Add Port. 11. Select LPR Port. Click New Port…. 12. Ent

Strany 84

CN2610 User’s Manual Setting Up Printer 12-15 14. Select the printer’s manufacturer and model name. Click Next to continue. 15. Enter the print

Strany 85

CN2610 User’s Manual Setting Up Printer 12-16 17. Print a test page to verify that the printer is configured correctly, and then click OK to finish

Strany 86

CN2610 User’s Manual Setting Up Printer 12-17 4. Select Local printer, and click Next to continue. 5. Select Create a new port:, and then selec

Strany 87

CN2610 User’s Manual Setting Up Printer 12-18 6. Enter CN2610’s IP Address, and then enter the Print Queue’s name. Click OK to continue. 7. Selec

Strany 88

CN2610 User’s Manual Setting Up Printer 12-19 9. Select Shared when prompted with questions asking if the printer is to be shared or not, and then

Strany 89

CN2610 User’s Manual Setting Up Printer 12-20 11. If you want to print a test page, reboot Windows 2000, select this printer, and click Print Test

Strany 90 - Setting Up Device Control

CN2610 User’s Manual Getting Started 2-8 4. Select a directory in which to install the CN2610 Utility, and then click Next. 5. Click Next to cont

Strany 91

1133 Chapter 13 Setting Up Multiplex In this chapter, we describe how to configure Moxa CN2610 as a Multiplexor and De-Multiplexor. Using the Mult

Strany 92

CN2610 User’s Manual Setting Up Multiplexor 13-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility

Strany 93

CN2610 User’s Manual Setting Up Multiplexor 13-3Selecting the Application The Multiplex application uses two Async Servers. One of the servers (call

Strany 94

CN2610 User’s Manual Setting Up Multiplexor 13-4CN2610-8 CN2610-8_19 V2.0 PORT MENU --------------

Strany 95 - Configuring RAW Mode

CN2610 User’s Manual Setting Up Multiplexor 13-5CN2610-8 CN2610-8_19 V2.0 ----------------------

Strany 96

CN2610 User’s Manual Setting Up Multiplexor 13-6Setting Value Notes NecessityTCP port number Each of CN2610’s serial ports is mapped to a TCP p

Strany 97

CN2610 User’s Manual Setting Up Multiplexor 13-7Configuring the “Device” CN2610 1. From the MAIN MENU, select Port, and then press Enter. CN2610-8

Strany 98

CN2610 User’s Manual Setting Up Multiplexor 13-8CN2610-8 CN2610-8_19 V2.0 -----------------------

Strany 99 - ASPP Examples for Unix

CN2610 User’s Manual Setting Up Multiplexor 13-9CN2610-8 CN2610-8_19 V2.0 -----------------------

Strany 100 - ASPP Examples for Windows

CN2610 User’s Manual Setting Up Multiplexor 13-10Setting Value Notes Necessity Quit Key ^E Defines the Quit key used to disconnect the link bet

Strany 101 - Setting Up Raw UDP

CN2610 User’s Manual Getting Started 2-9 6. Wait while the PComm Lite software is installed. 7. Click Close.

Strany 102

CN2610 User’s Manual Setting Up Multiplexor 13-1111. Repeat the previous steps for ports 5, 7, and 8. CN2610-8 CN2610-8_19

Strany 103 - Selecting the Application

CN2610 User’s Manual Setting Up Multiplexor 13-12Setting Value Notes Speed 50 bps to 921.6 Kbps Transmission rate Bits 5, 6, 7, 8 Data bits St

Strany 104 - Configuring RAW UDP Mode

CN2610 User’s Manual Setting Up Multiplexor 13-13Restart 1. From the MAIN MENU, select Restart. CN2610-8 CN2610-8_19 V2.0

Strany 105 - Configuring the Serial Ports

1144 Chapter 14 Setting Up Routing Routing is the main process used by Internet hosts to deliver packets. The Internet uses a hop-by-hop routing m

Strany 106

CN2610 User’s Manual Setting Up Routing 14-2Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utility by Te

Strany 107 - Restart

CN2610 User’s Manual Setting Up Routing 14-3What is RIP? RIP (Routing Information Protocol) is a protocol used widely to manage routing information

Strany 108 - Data Acquisition System

CN2610 User’s Manual Setting Up Routing 14-4CN2610-8 CN2610-8_19 V2.0 --------------------------

Strany 109 - Async Server CN2610-8

CN2610 User’s Manual Setting Up Routing 14-5Setting Value Notes NecessityEntry 01-32 A maximum of 32 entries are allowed. Fixed Gateway xxx.x

Strany 110

CN2610 User’s Manual Setting Up Routing 14-6Configuring Routes to the Internet and Intranet CN2610Console ServerTCP/IPPC NotebookModemEthernet203.67

Strany 111 - DRDAS Mode

CN2610 User’s Manual Setting Up Routing 14-7Configuring Multiple-Point Routes CN2610Console ServerCN2610Console ServerCN2610Console ServerTCP/IPEthe

Strany 112

CN2610 Async Server User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance wit

Strany 113

CN2610 User’s Manual Getting Started 2-10 8. When the installation is complete, select Start Æ Programs Æ PComm Terminal Emulator to run PComm Term

Strany 114

CN2610 User’s Manual Setting Up Routing 14-8Save When exiting the SERVER MENU, you will be prompted to save settings. Press Y to save. CN2610-8

Strany 115

1155 Chapter 15 Administrative Utilities In this chapter, we show how to use CN2610 administrative utilities, which include Ping (to see if a LAN

Strany 116 - Setting Up Reverse Terminal

CN2610 User’s Manual Administrative Utilities 15-2Ping Ping is used to test network hardware connectivity and whether a network host is active. 1.

Strany 117

CN2610 User’s Manual Administrative Utilities 15-33. Each item is discussed in the following subsections. CN2610-8 CN2610-

Strany 118

CN2610 User’s Manual Administrative Utilities 15-4Network 1. From the MONITOR MENU, select Network, and then press Enter. CN2610-8

Strany 119 - Configuring RTELNET Mode

CN2610 User’s Manual Administrative Utilities 15-5ErrHeader: Received UDP datagram packet with incorrect header. Sent: Sent UDP datagram packe

Strany 120

CN2610 User’s Manual Administrative Utilities 15-6Routing 1. From the MONITOR MENU, select Routing, and then press Enter. CN2610-8

Strany 121

CN2610 User’s Manual Administrative Utilities 15-7CN2610-8 CN2610-8_19 V2.0 --------------------

Strany 122

CN2610 User’s Manual Administrative Utilities 15-8CN2610-8 CN2610-8_19 V2.0 -----------------------------------

Strany 123 - Setting Up Terminal

CN2610 User’s Manual Administrative Utilities 15-9 4. When the Download ok! window appears, click OK. Console Terminal Upgrade 1. Run Start Æ Pr

Strany 124

CN2610 User’s Manual Getting Started 2-11 11. Click the Terminal tab and select VT100 for terminal type. Press Enter to confirm. 12. Type 1 to se

Strany 125

CN2610 User’s Manual Administrative Utilities 15-10 3. On the Communication Parameter page, select COM2 for Ports, 115200 for Baudrate, 8 for Data

Strany 126 - Configuring TERM_ASC Mode

CN2610 User’s Manual Administrative Utilities 15-11 6. Use the following keystrokes to navigate CN2610’s console utility. Action Key Move [Up/Dow

Strany 127

CN2610 User’s Manual Administrative Utilities 15-12 4. When you see Start loading file … near the bottom of the screen, click the Port Manager menu

Strany 128 - Configuring TERM_BIN Mode

CN2610 User’s Manual Administrative Utilities 15-13 6. In the File Transfer window select XModem-CheckSum for Protocol and Transmit for Direction,

Strany 129

CN2610 User’s Manual Administrative Utilities 15-14 8. The CN2610 will store the new firmware in its Flash ROM, and then restart the entire system,

Strany 130

CN2610 User’s Manual Administrative Utilities 15-15NOTE The file must contain at least a host, and if the login ID is different on the remote host,

Strany 131

CN2610 User’s Manual Administrative Utilities 15-16CN2610-8 CN2610-8_19 V2.0 ----------------------------------

Strany 132

CN2610 User’s Manual Administrative Utilities 15-17 5. When you see Start loading file … near the bottom of the screen, click the Port Manager menu

Strany 133

CN2610 User’s Manual Administrative Utilities 15-18 7. In the File Transfer window select XModem-CheckSum for Protocol, and Receive for Direction.

Strany 134 - Setting Up Multi-host TTY

CN2610 User’s Manual Administrative Utilities 15-19Remote RCP Export As we pointed out earlier, RCP is a file transfer protocol that does not requir

Strany 135

CN2610 User’s Manual Getting Started 2-12 13. The MAIN MENU is shown below. (NOTE: Click Edit Æ Font to choose a different font for the MAIN MENU.)

Strany 136

CN2610 User’s Manual Administrative Utilities 15-203. From the SETTING MENU, select Import, and then press Enter. 4. Select Console port (using

Strany 137 - Configuring FIXTTY Mode

CN2610 User’s Manual Administrative Utilities 15-216. Select Port Manager Æ File Transfer from the menu. 7. In the File Transfer window select XM

Strany 138

CN2610 User’s Manual Administrative Utilities 15-229. CN2610 will import settings from the file. Remote RCP Import As we pointed out earlier, RCP i

Strany 139

CN2610 User’s Manual Administrative Utilities 15-233. Press Enter to confirm that you wish to erase all settings and restore the default settings.

Strany 140 - Setting up Hosts

AA Appendix A Troubleshooting In this appendix, we give solutions to various problems you may come across when using CN2610. The following topics

Strany 141 - Terminal Access

CN2610 User’s Manual Troubleshooting A-2Console Terminal Problems Problem: No message is displayed on the console terminal. Solutions: ¾ Check to s

Strany 142 - Using Fixed TTY Driver

CN2610 User’s Manual Troubleshooting A-3RxTx1 2 3 4 5 6 7 8 9 10111213141516ResetReadySELMENUCN251016 port RS-232 Async ServerReset Problem: I used

Strany 143 - Setting Up Dialin/out

CN2610 User’s Manual Troubleshooting A-4¾ MOXA does not recommend that you setup 2 LAN ports in the same physical network and subnet. You might enc

Strany 144

CN2610 User’s Manual Troubleshooting A-5Saving CN2610’s Parameters Question: How can I save CN2610’s parameters to recover from unexpected power fai

Strany 145

CN2610 User’s Manual Troubleshooting A-6¾ Check to see if the CN2610’s SLIP port baudrate (in the Port Æ Line menu) is the same as the remote host’

Strany 146 - Configuring PPPD/PPP Mode

CN2610 User’s Manual Getting Started 2-13CN2610-8 CN2610-8_19 V2.0 -----------------------------

Strany 147

BB Appendix B RADIUS Server Managing dispersed serial lines and modem pools for large numbers of users can create the need for significant adminis

Strany 148 - Configuring SLIPD/SLIP Mode

CN2610 User’s Manual RADIUS Server B-2What is RADIUS? Definition Remote Authentication Dial-up User Service, or RADIUS, is the standard for centrali

Strany 149

CN2610 User’s Manual RADIUS Server B-3CN2610-8 CN2610-8_19 V2.0 --------------------------------

Strany 150 - Configuring Dynamic Mode

CN2610 User’s Manual RADIUS Server B-4+------------------------------------------------+| Enable Detail-setting || TERM_BIN mode [yes] [Term

Strany 151

CN2610 User’s Manual RADIUS Server B-5+------------------------------------------------+| Key Mapping : || Max. Sessions : [ 8 ] ||

Strany 152

CN2610 User’s Manual RADIUS Server B-6OS Command SCO OpenServer #mount -f ISO9660, filemode=444 <device> Example: #mount-f ISO9660, filemode=

Strany 153

CN2610 User’s Manual RADIUS Server B-7+--------------------------------------------------------------------+ | Basic Configuration | +----

Strany 154

CN2610 User’s Manual RADIUS Server B-8+--------------------------------------------------------------------+ | User Permission Maintenance

Strany 155

CN2610 User’s Manual RADIUS Server B-9+--------------------------------------------------------------------+ | Extended Permission Maintenance

Strany 156

CN2610 User’s Manual RADIUS Server B-10+--------------------------------------------------------------------+ | User List | +-----------

Strany 157 - Optional Welcome Message

CN2610 User’s Manual Getting Started 2-14Server Configuration—LAN 1. From the MAIN MENU, use the arrow keys to select Server, and then press Enter.

Strany 158

CN2610 User’s Manual RADIUS Server B-11Radius Hash Key:[ ]Æ RADIUS encryption key, must be the same key in the proxy server end. Select “OK” to save

Strany 159

CN2610 User’s Manual RADIUS Server B-12 5. Select Service. Check the RADIUS ports. [Authentication] 1645 [Accounting] 1646 6. Select Client, and

Strany 160 - Setting Up Printer

CN2610 User’s Manual RADIUS Server B-13Setting up Windows 2000 Hosts 1. Click Start Æ Programs Æ Administrative Tools Æ Routing and Remote Access.

Strany 161

CN2610 User’s Manual RADIUS Server B-14 6. Specify an IP address.

Strany 162

CN2610 User’s Manual RADIUS Server B-15 7. Select Yes, I want to use a RADIUS server, and then click Next to start using this function.

Strany 163 - Configuring RAW PRN Mode

CN2610 User’s Manual RADIUS Server B-16Setting up Windows 2003 Hosts Windows 2003 uses IAS service instead of RADIUS service. For this reason, you n

Strany 164

CN2610 User’s Manual RADIUS Server B-17 5. Select NEW RADIUS Client to add a new RADIUS client. You will then be able to start using this function.

Strany 165 - Configuring LPD PRN Mode

CC Appendix C SNMP Agent with MIB II Simple Network Management Protocol agent software is built into CN2610. The software supports cold/warm start

Strany 166

CN2610 User’s Manual SNMP Agent with MIB II C-2 UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutP

Strany 167

DD Appendix D Pin Assignments and Cable Wiring In this appendix, common pin assignment and cable wiring diagrams are presented. The following topi

Strany 168 - Setting up Unix Hosts

CN2610 User’s Manual Getting Started 2-15determine if the destination TCP/IP host is on the same subnet. If the address is on the same subnet, a con

Strany 169

CN2610 User’s Manual Pin Assignments and Cable Wiring D-2Pin Assignments 10/100BaseTX Port Pin Assignment Pin Signal 1 Tx+ 2 Tx- 3 Rx+

Strany 170 - Setting up a LINUX Host

CN2610 User’s Manual Pin Assignments and Cable Wiring D-3Async RS-232 Port Cable Wiring 8-pin RJ45 to Male DB9 for CN2610 CN2610DSRRTSGNDTxDRxDDCDCT

Strany 171 - Setting up Windows Hosts

CN2610 User’s Manual Pin Assignments and Cable Wiring D-48-pin RJ45 to Male DB25 for CN2610 CN2610DSRRTSGNDTxDRxDDCDCTSDTRRS-232DeviceDTRCTSGNDRxDTx

Strany 172

EE Appendix E LCM Display For first time installation, we recommend using the LCM display and four push buttons to configure the IP address. Basic

Strany 173

CN2610 User’s Manual LCM Display E-2C N 2 6 1 0 - 1 6 _ 0 3 1 9 2 . 1 6 8 . 1 2 7 . 2 5 4 MENU M a i n M e n U S e r v e

Strany 174

CN2610 User’s Manual LCM Display E-3The first type involves entering numbers, such as IP addresses, Netmasks, etc. In this case, you change the numb

Strany 175

FF Appendix F Service Information In this appendix, we show you how to contact Moxa for information about this and other products, and how to repo

Strany 176

CN2610 User’s Manual Service Information F-2MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers rec

Strany 177

CN2610 User’s Manual Service Information F-3Problem Report Form MOXA CN2610 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Produc

Strany 178

CN2610 User’s Manual Service Information F-4Product Return Procedure For product repair, exchange, or refund, the customer must:  Provide evidenc

Strany 179

CN2610 User’s Manual Getting Started 2-16RADIUS server IP—The IP address of the RADIUS (Remote Authentication Dial-In User Service) server is used t

Strany 180 - Setting Up Multiplex

CN2610 User’s Manual Getting Started 2-17CN2610-8 CN2610-8_19 V2.0 SERVER MENU--------------------

Strany 181

CN2610 User’s Manual Getting Started 2-18CN2610-8 CN2610-8_19 V2.0 -----------------------------

Strany 182 - Equipment

CN2610 User’s Manual Getting Started 2-19CN2610-8 CN2610-8_19 V2.0 -----------------------------

Strany 183

Table of Contents Chapter 1 Introduction...1-1 Product Fe

Strany 184

CN2610 User’s Manual Getting Started 2-20CN2610-8 CN2610-8_19 V2.0 ---------------------------------

Strany 185

33 Chapter 3 Knowing Your Application This chapter discusses a variety of applications for CN2610 Async Server. Refer to the diagrams in each sect

Strany 186

CN2610 User’s Manual Knowing Your Application 3-2Windows Real COM (NT Real COM) 12345678Serial portsAC POWER 100-240V, 47-63HzConsole LAN1 LAN29 101

Strany 187

CN2610 User’s Manual Knowing Your Application 3-3Linux Real TTY/Unix Fixed TTY (NT Real COM) CN2610ttyS1 ttyS2 ... ttySNEthernetLinux,

Strany 188

CN2610 User’s Manual Knowing Your Application 3-4Device Control (Device Control) RTU RTU RTUIBM SCO UNIXSUNTCP/IP{sio_open(..)sio_open(..)sio_read(.

Strany 189

CN2610 User’s Manual Knowing Your Application 3-5UDP Communication (Raw UDP) CN2610TCP/IPSerialFinger PrinterEthernetUDP datagramR R12345678Serial p

Strany 190

CN2610 User’s Manual Knowing Your Application 3-6Dual-host Redundant Data Acquisition System (DRDAS) LAN ALAN BRS-232/422/485Remote Terminal Unit (R

Strany 191

CN2610 User’s Manual Knowing Your Application 3-7LAN ALAN BRS-232/422/485Remote Terminal Unit (RTU)PrimaryDataPrimary PCBackup PCRxTx1 2 3 4 5 6 7 8

Strany 192

CN2610 User’s Manual Knowing Your Application 3-8Console Management (Reverse Terminal) CN2610TCP/IPTelnetServerRS-232Reverse TelnetmodeRouter Server

Strany 193 - Setting Up Routing

CN2610 User’s Manual Knowing Your Application 3-9Terminal Access (Terminal) CN2610TCP/IPRS-232TerminalTerminal TerminalUnixWindows NTRxTx1 2 3 4 5 6

Strany 194

Configuring the Serial Ports... 4-5 Save...

Strany 195 - Configuring RIP

CN2610 User’s Manual Knowing Your Application 3-10Multi-host TTY (Multi-host TTY) CN2610Swith Session Between differentUnix server by Hot KeyTCP/IPT

Strany 196 -

CN2610 User’s Manual Knowing Your Application 3-11Dial-in/Out-of-Band Management (Dialin/out) CN2610TCP/IPRouterUNIX Server PC NotebookModemPPPDialo

Strany 197 - Static Routing Examples

CN2610 User’s Manual Knowing Your Application 3-12Network Printer (Printer) CN2610TCP/IPRS-232Printer Printer Printer PrinterUnixIBMRxTx1 2 3 4 5 6

Strany 198 - 16 port RS-232 Async Server

CN2610 User’s Manual Knowing Your Application 3-13Multiplexor Access (Multiplex) RouterSwitchCode ReaderRS-232RS-232IBM workstationwith multiport bo

Strany 199

44 Chapter 4 Setting Up Windows Real COM/Linux Real TTY/Unix Fixed TTY CN2610 Async Server supports Real COM/TTY drivers for Windows and Linux, al

Strany 200

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-2 Accessing the Console Utility NOTE In this section, we show how to access CN

Strany 201 - Administrative Utilities

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-3Selecting the Application Open Port Menu Æ Mode to configure the NT Real COM

Strany 202 - Monitor

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-45. ASPP mode is selected by default, since it is the only mode associated wi

Strany 203

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-5Setting Value Notes Necessity TCP data port 950 – 965 The host uses this

Strany 204 - Network

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-6CN2610-8 CN2610-8_19 V2.0

Strany 205

Accessing the Console Utility ... 10-2 Selecting the Application...

Strany 206 - PPP-Trace

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-7CN2610-8 CN2610-8_19 V2.0

Strany 207 - Diagnostic

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-8 3. When the Welcome to the Add Hardware Wizard window opens, click Next to

Strany 208 - Upgrade

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-9 5. The next window to open will ask you if the hardware is connected. Selec

Strany 209 - Console Terminal Upgrade

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-10 7. Select Install the hardware that I manually select from a list (Advance

Strany 210

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-11 9. The window that opens next will ask you to select the device driver you

Strany 211

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-12 11. Select the correct CN2610 model, and then click Next to continue. 12.

Strany 212

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-13 13. Although the next window to open states that the software hasn’t passe

Strany 213

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-1415. You can select the CN2610 that was located automatically, or select Man

Strany 214 - Remote RCP Upgrade

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-15 Installing Ports 1. After the CN2610 server driver has been installed, Win

Strany 215

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-16 3. Although the next window to open states that the software hasn’t passed

Strany 216 - Console Terminal Export

Configuring the Static Routing Table ... 14-4 Static Routing Examples...

Strany 217

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-17 5. After Moxa Port 0 is installed, steps 1 to 4 will be repeated 7 or 15 t

Strany 218

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-18 Configuring CN2610 in a Windows XP/2003 Environment After the CN2610 driver

Strany 219 - Console Terminal Import

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-19 2. Click the Configuration tab. 3. Click Settings to configure CN2610’s

Strany 220

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-20 4. On the Basic Configuration page, modify Server Name, IP Address, Netmas

Strany 221

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-21 6. The Access Control page allows you to set up access rights for each of

Strany 222 - Default

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-227. Click Modify to save all Property Sheet settings and return to the Prope

Strany 223 - Press any key to cancel

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-23 10. Modify the settings that need to be changed, and then click OK. Setti

Strany 224 - Appendix A Troubleshooting

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-24 3. When the Welcome to the Add Hardware Wizard window opens, click Next to

Strany 225 - Console Terminal Problems

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-25 5. In the Choose a Hardware Device window, select Add a new device, and th

Strany 226

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-26 7. In the Hardware Type window, select Multi-port serial adapters from the

Strany 227 - Terminal Port Problems

Setting up Windows 2003 Hosts...B-16 Appendix C SNMP Agent with MIB II ...

Strany 228 - SLIP/PPP Connection Problems

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-27 9. After locating the win2k folder, select the driver file NPSERVER.INF, a

Strany 229 - RADIUS Problems

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-28 11. The Wizard will start installing the Server driver, and automatically

Strany 230 - Appendix B RADIUS Server

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-29 13. You can select the CN2610 that was located automatically, or select M

Strany 231 - Setting up CN2610

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-30 14. The next window reports that the driver was installed, and port driver

Strany 232 - Dialin/out—Dynamic Mode

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-31 2. After the installation is complete, you can check Ports (COM & LPT)

Strany 233 - Dialin/out—PPP/PPPD Mode

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-32to configure, and select Properties. 2. Click the Configuration tab. 3.

Strany 234 - Setting up UNIX Hosts

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-33 4. On the Basic Configuration page, modify Server Name, IP Address, Netmas

Strany 235 - RADIUS Server Configuration

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-34 6. The Access Control page allows you to set up access rights for each of

Strany 236 - Add/Modify permission group

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-357. And then click OK to return to the Access Control page. 8. Click OK to

Strany 237 - Basic Permission Maintenance

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-36 10. Check the box(es) next to the port(s) you would like to modify, and th

Strany 238 - User Settings

11 Chapter 1 Introduction Welcome to Moxa CN2610 Dual LAN Async Server. Models are available with 8 or 16 asynchronous RS-232 ports, and all model

Strany 239 - RADIUS proxy

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-37 Setting up Windows 95/98/ME/NT Hosts In this section, we explain how to set

Strany 240 - Setting up Windows NT Hosts

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-38 4. Select Custom mode, and then click Next to continue. 5. Select a Dest

Strany 241

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-39 7. After the driver is installed, NPort Pro Manager and the Add Server Wiz

Strany 242

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-40 9. If necessary, enter a different IP address in the Server IP address box

Strany 243 - 6. Specify an IP address

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-41 11. For added security, set a password for the CN2610. Check the Auto-Save

Strany 244

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-42 13. The server and ports will be displayed in the NPort Server Manager win

Strany 245

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-43 2. Right click the CN2610 you wish to configure, click the right mouse but

Strany 246

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-44 4. On the Password page, set up a password for this CN2610 for added secur

Strany 247 - Supported SNMP variables

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-45 6. The Transmission page lets you to select a Transmission Mode and Tx FIF

Strany 248

CN2610 User’s Manual Windows Real COM/Linux Real TTY/Unix Fixed TTY 4-46 8. The Advanced page allows you to add routes to CN2610. However, since CN

Strany 249

CN2610 User’s Manual Introduction 1-2Product Features Hardware y Dual LAN ports (auto-detecting 10/100 Mbps Ethernet) y Surge protection for each

Strany 250 - Cable Wiring

55 Chapter 5 Setting Up Device Control Device Control applications use standard Linux/Unix Socket programming for Linux/Unix systems, or WinSock p

Strany 251

CN2610 User’s Manual Setting Up Device Control 5-2 Accessing the Console Utility NOTE In this section, we show how to access CN2610’s console utilit

Strany 252

CN2610 User’s Manual Setting Up Device Control 5-3Selecting the Application Open Port Menu Æ Mode to configure the Device Control application. 1. F

Strany 253 - Appendix E LCM Display

CN2610 User’s Manual Setting Up Device Control 5-45. ASPP mode is selected by default. CN2610-8 CN2610-8_19 V2.0

Strany 254

CN2610 User’s Manual Setting Up Device Control 5-5CN2610-8 CN2610-8_19 V2.0 --------------------

Strany 255

CN2610 User’s Manual Setting Up Device Control 5-6Setting Value Notes Necessity TCP data port 950 – 965The host uses this value to determine whi

Strany 256 -  MOXA Internet Services

CN2610 User’s Manual Setting Up Device Control 5-7CN2610-8 CN2610-8_19 V2.0 --------------------

Strany 257 - MOXA Internet Services

CN2610 User’s Manual Setting Up Device Control 5-84. Press Esc to return to the PORT MENU. Configuring the Serial Ports Open Port Menu Æ Line to co

Strany 258 - MOXA CN2610 Series

CN2610 User’s Manual Setting Up Device Control 5-94. Press ESC to return to the PORT MENU. Save When exiting the SERVER MENU, you will be prompted

Strany 259 - Product Return Procedure

CN2610 User’s Manual Setting Up Device Control 5-10ASPP Library Introduction The CN2610 Documentation and Software CD contains example programs that

Komentáře k této Příručce

Žádné komentáře