Moxa Technologies C104P Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro ne Moxa Technologies C104P. Moxa Technologies C104P User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
C104P User’s Manual
Universal 4 Port Serial Board
May 1999 (7th Edition)
The content of this manual is also available in CD-ROM and at Moxa Web Site.
Moxa Technologies Co., Ltd.
Tel: +866-2-8665-6373
Fax: +886-2-8665-6372
www.moxa.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 73 74

Shrnutí obsahu

Strany 1 - C104P User’s Manual

C104P User’s ManualUniversal 4 Port Serial BoardMay 1999 (7th Edition)The content of this manual is also available in CD-ROM and at Moxa Web Site.Moxa

Strany 2

1-4 C104P User’s ManualFeaturesv Custom-designed ASIC, compact board size (half-size)v No switch no jumper, easily configured by softwarev In

Strany 3 - MOXA Internet Services

IntroductionC104P User’s Manual 1-5Check ListUpon unpacking the C104P package, you should find the following items in thepackage,v C104P

Strany 4 - About This Manual

1-6 C104P User’s ManualInstallation GuideThis section gives a brief summary of how to install the C104P under eachsupported operating system. Th

Strany 5 - Table of Contents

C104P User’s Manual 2-122 2 Hardware InstallationThe installation of the C104P consists of hardware and software installation. Thehardware install

Strany 6

2-2 C104P User’s ManualNow you should do either the normal hardware installation (detailed in the latersection, “Hardware Installation with

Strany 7 - 1 Introduction

Software InstallationC104P User’s Manual 2-35. DO power OFF and then ON (or Reset) the PC. (Please cold start.)6. Restart System (Windows NT/95/98)

Strany 8 -

2-4 C104P User’s Manual2. Power off the PC.3. Make sure no hardware conflict and plug the board in a free 16-bit slot of the PC,one board at a t

Strany 9 - Wide Applications

Software InstallationC104P User’s Manual 2-51. Run the utility “Io-irq.exe” contained in the driver diskette to set up I/O address,IRQ and INT vect

Strany 10 - Features

2-6 C104P User’s Manual3. Enter the CAP address of the C104P board to be configured.4. Configure the following parameters as necessary.Port Inde

Strany 11 - Check List

Software InstallationC104P User’s Manual 2-7INT Vector Enter the interrupt vector I/O address for all ports. I/O addressfor interrupt vector is

Strany 12 - Installation Guide

C104P User’s ManualThe software described in this manual is furnished under a license agreement and may be used only inaccordance with the terms of th

Strany 13 - 2 Hardware Installation

2-8 C104P User’s Manual

Strany 14 - Quick Hardware Installation

C104P User’s Manual 3-133 3 Software InstallationIn this chapter, the software driver installation, configuration and driverupdate/remova

Strany 15 - Software Installation

3-2 C104P User’s ManualInstalling DriverFollowing is the procedure for installing the C104P driver for the first time underWindows NT 4.0.Note !

Strany 16 - 2-4 C104P User’s Manual

Software InstallationC104P User’s Manual 3-35. Select “MOXA Smartio/Industio Family multiport board” in the “SelectOEM Option” dialog bo

Strany 17

3-4 C104P User’s ManualNote ! You may go directly to the step 8 if you need not change any setting.7. In the “Property” dialog box, select the d

Strany 18 - 2-6 C104P User’s Manual

Software InstallationC104P User’s Manual 3-5l Port NumberYou have to set up all the ports of the board with the desired “COMnumber”, which sh

Strany 19

3-6 C104P User’s Manual9. When configuration is done, click on [OK] button in the “Network Settings”dialog box.10.Restart Windows NT system. T

Strany 20 - 2-8 C104P User’s Manual

Software InstallationC104P User’s Manual 3-7Note ! Once the board and the driver are installed and the driver restartssuccessfully, you

Strany 21 - 3 Software Installation

3-8 C104P User’s Manual3. Click on the [Property] button to open the “Moxa Smartio/IndustioConfiguration Panel” dialog box. Please see

Strany 22 - Installing Driver

Software InstallationC104P User’s Manual 3-9Updating DriverTo update the driver for the C104P board, simply remove the driver, as described inthe n

Strany 23

MOXA Internet ServicesCustomer’s satisfaction is always our number one concern. To ensure that customers get the full benefitof our services, Moxa Int

Strany 24 - 3-4 C104P User’s Manual

3-10 C104P User’s ManualInstalling DriverUp to four C104P boards can be installed together as long as the I/O addresses andIRQ number resources

Strany 25

Software InstallationC104P User’s Manual 3-11Note ! Go directly to the step 7 if you need not change any setting.6. In the “Property” dialog box, s

Strany 26 - 3-6 C104P User’s Manual

3-12 C104P User’s Manuall Port NumberYou have to set up all the ports of the board with the desired “COMnumber”, which should not conflict

Strany 27 - Configuring Board and Port

Software InstallationC104P User’s Manual 3-138. Restart Windows 95/98 system.Note ! The latest configuration will not take effect unless th

Strany 28 - 3-8 C104P User’s Manual

3-14 C104P User’s ManualConfiguring Board and PortIf you already have installed the driver and want to re-configure the C104P boardand ports, ad

Strany 29 - Windows 95/98

Software InstallationC104P User’s Manual 3-15Updating DriverOpen [Control Panel] icon, and then [System] icon, and then select [DeviceMa

Strany 30

3-16 C104P User’s ManualRemoving DriverOpen [Control Panel] icon, and then [Add/Remove Programs] icon, and thenselect [Install/Uninsta

Strany 31 - 3-11

Software InstallationC104P User’s Manual 3-17DOSMOXA DOS API-232 is a software package that assists users to develop and/ordebug programs

Strany 32 - 3-12 C104P User’s Manual

3-18 C104P User’s ManualAfter installation is complete, you will be prompted to proceed running setupprogram. It is strongly recommen

Strany 33 - 3-13

Software InstallationC104P User’s Manual 3-192. Press Enter to pop up the SETUP dialog box. In the SETUP dialog box, PressF8 to specify the CAP Ad

Strany 34

About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog

Strany 35 - Updating Driver

3-20 C104P User’s Manual3. Now the configuration of the desired C104P board will be shown along withother default settings, such as port numb

Strany 36 - Removing Driver

Software InstallationC104P User’s Manual 3-21You may now enter/modify each port’s configuration. These displayed valuesare the port initial values

Strany 37

3-22 C104P User’s ManualF6: INT vector: This is to set interrupt vector for each port. You can setthis feature to “Yes” (default) and gain best

Strany 38 - Driver Setup

Software InstallationC104P User’s Manual 3-23It means the C104P driver is installed properly. At this point, you are ready toexecute

Strany 39 - 3-19

3-24 C104P User’s ManualInstalling Driver1. Run WININST.EXE in the DOS/Windows 3.x driver diskette, click [OK] inthe “Driver Installation” dialo

Strany 40 - 3-20 C104P User’s Manual

Software InstallationC104P User’s Manual 3-25If you need to modify the settings, click [Modify], type in the desired I/Oaddress in the

Strany 41 - 3-21

3-26 C104P User’s ManualConfiguring DriverThe configuration program, Configuration, in the “MOXA Standard COMMDriver” program group,

Strany 42 - Loading Driver

Software InstallationC104P User’s Manual 3-27Removing DriverThe program, Driver Removal, in the “MOXA Standard COMM Driver” programgroup is provide

Strany 43 - Windows 3.x

3-28 C104P User’s Manual

Strany 44

C104P User’s Manual 4-144 4 Serial Programming ToolsMoxa supports easy but powerful serial programming library and communicationtroubleshooting ut

Strany 45 - 3-25

Table of ContentsIntroduction... 1-1Overview...

Strany 46 - Configuring Driver

4-2 C104P User’s ManualPComm Programming LibraryThe serial communication library is to assist users to develop programs for serialcommunications

Strany 47

Serial Programming ToolsC104P User’s Manual 4-3Diagnostic (for MOXA boards only)A convenient diagnostic program provides internal and externa

Strany 48 - 3-28 C104P User’s Manual

4-4 C104P User’s ManualMonitor (for MOXA boards under Windows NT Only)A useful port status monitoring program allows you to watch the selected M

Strany 49 - 4 Serial Programming Tools

Serial Programming ToolsC104P User’s Manual 4-5Terminal EmulatorThe Terminal Emulator features multi-windows and supports terminal types o

Strany 50 - Utilities

4-6 C104P User’s ManualDOSInstallationAPI-232 Library is the professional serial programming tool for DOS. It is installedautomatically along wi

Strany 51 - Serial Programming Tools

Serial Programming ToolsC104P User’s Manual 4-7There are three major functions in Data Scope utility:1. The Data Scope utility offers transparent m

Strany 52 - 4-4 C104P User’s Manual

4-8 C104P User’s ManualDiagnoseThe Diagnose, BIN\DIAGNOSE.EXE, is a utility that can help users to diagnosethe hardware condition of each port o

Strany 53 - Terminal Emulator

Serial Programming ToolsC104P User’s Manual 4-9UtilityThe utility, TTY, in the “MOXA Standard COMM Driver” program group isintended to h

Strany 54 - DOS API-232 Library

4-10 C104P User’s Manual

Strany 55

C104P User’s Manual 5-155 5 Connection Cable and Cable WiringIn serial data communications, the term DTE is for Data Terminal Equipment likePC COM

Strany 56

Windows NT and Windows 95/98...4-1Installation...

Strany 57 - Existing Applications

5-2 C104P User’s ManualType 1: To connect C104P to a DTE device.PC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt4CNull Modem CableC10

Strany 58 - 4-10 C104P User’s Manual

Connection Cable and Cable WiringC104P User’s Manual 5-3Type 2: To connect C104P to a DCE device.Modem,or any DCE DeviceOpt4CStraight-through Cable

Strany 59 - RS-232 Cable Wiring

5-4 C104P User’s ManualType 3: To connect C104P to a DTE with 3-pin wiring.If the “Hardware flow control” feature is set to “ON”, you must

Strany 60 - 5-2 C104P User’s Manual

C104P User’s Manual 6-166 6 TroubleshootingCommon C104P problems and possible solutions are listed below. If you still haveproblems, contact you

Strany 61 - C104P DCE Device

6-2 C104P User’s ManualSoftware Causes and Solutions:a. C104P checks the line status (CTS) before it sends data out if the RTS/CTSflow control

Strany 62 - 5-4 C104P User’s Manual

TroubleshootingC104P User’s Manual 6-3irq.exe can access to the board. The following procedure instructs user to recover once the CAP is unknown.St

Strany 63 - 6 Troubleshooting

6-4 C104P User’s ManualStep 8. Power off the PC.OFFStep 9. Remove the jumper on position JP1.jumperJP1RemoveStep 10. Power on the PC.ONWindow

Strany 64 - 6-2 C104P User’s Manual

TroubleshootingC104P User’s Manual 6-5a. Some partial decoded network board may interfere with our board. Pleaseavoid from using 0x300 as I/O addr

Strany 65 - Troubleshooting

6-6 C104P User’s Manualc. The I/O addresses may conflict with other devices, please change another setof I/O address such as I/O:0x280, Interrup

Strany 66 - Windows NT

C104P User’s Manual A-1AAppppeennddiixxA Technical ReferenceSpecificationsv Bus interface: ISA (EISA compatible)v Number of ports: 4v I/O addres

Strany 67

C104P User’s Manual 1-111 1 IntroductionOverviewThe Standard Multiport Async SolutionsThe term Smartio stands for smart multiport serial I/O solut

Strany 68 - 6-6 C104P User’s Manual

A-2 C104P User’s ManualSmartio C104 SeriesWindows NT3Windows 95/98 3DOS 3Windows 3.x 3Linux RSCO UNIX/OpenServer CSCO XENIX CQNX CFreeBSD COS/2

Strany 69 - A Technical Reference

Technical ReferenceC104P User’s Manual A-3PC I/O Port Address MapThe following is the list of the I/O port addresses commonly used, which is good f

Strany 70 - A-2 C104P User’s Manual

A-4 C104P User’s ManualDB37 Connector PinoutsThe following lists the pin assignments of the DB37 connector on the bracket.Pin no. Signal Pin no.

Strany 71 - PC I/O Port Address Map

Problem Report FormC104P Customer name: Company: Tel: Fax: Email: Date:1. Moxa Product: C104P Serial Number: ____________2. Moxa Driver Version: ___

Strany 72 - DB37 Connector Pinouts

Return ProcedureFor product repair, exchange or refund, you must:v Provide evidence of original purchase. v Fill out the Problem Report Form (PRF) a

Strany 73 - Problem Report Form

1-2 C104P User’s ManualHardware Configuration Method C104P JP1TraditionalMultipoort BoardJumperON 1 23 4Switch...New :

Strany 74 - Return Procedure

IntroductionC104P User’s Manual 1-3Operating System SupportThe C104P is operational under most popular operating systems such as WindowsNT, Windows

Komentáře k této Příručce