Moxa Technologies INTELLIO C218 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Karty / adaptéry rozhraní Moxa Technologies INTELLIO C218. Moxa Technologies INTELLIO C218 User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 122
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Intellio C320Turbo User's Manual
An Advanced Professional Intelligent Multiport System for ISA bus with
Desktop and Rackmount Options
Nov. 1999 (4th Edition)
The content of this manual is also available in CD-ROM and at Moxa Web Site.
Moxa Technologies Co., Ltd.
Tel: +866-2-8665-6373
Fax: +886-2-8665-6372
www.moxa.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 121 122

Shrnutí obsahu

Strany 1 - Nov. 1999 (4th Edition)

Intellio C320Turbo User's ManualAn Advanced Professional Intelligent Multiport System for ISA bus withDesktop and Rackmount OptionsNov. 1999 (4th

Strany 2

1-2 Intellio C320Turbo User's ManualLow Host Processor OverheadThe Intellio C320Turbo is equipped with two high performance processors (TMS320)o

Strany 3 - User's Manual

5-14 Intellio C320Turbo User's ManualC32020T Link CableThere are two different types of link cables: 25-signal-pin link cable and 10-signal-pin

Strany 4 - MOXA Internet Services

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-1510-signal-pin Link Cable (for long range extension only)If the external p

Strany 5 - About This Manual

5-16 Intellio C320Turbo User's Manual

Strany 6 - Table of Contents

Intellio C320Turbo User's Manual 6-166 6 TroubleshootingCommon C320Turbo problems and possible solutions are listed below. If you stillhave prob

Strany 7

6-2 Intellio C320Turbo User's Manuale. Sometimes it happens when the total consumption of power in the system ishigher than the power supply can

Strany 8

TroubleshootingIntellio C320Turbo User's Manual 6-3c. IRQ settings of software and hardware do not match.3. “CPU/Basic Module not found” messag

Strany 9

6-4 Intellio C320Turbo User's ManualHardware Causes and Solutions:If the error message persists after check, return the unit for repair.As “E0”,

Strany 10

TroubleshootingIntellio C320Turbo User's Manual 6-5Windows NTThis section is specific for troubleshooting under Windows NT. For generalproblems

Strany 11 - Surge/Isolation Protection

6-6 Intellio C320Turbo User's Manual5. After system starts, error message “MOXA C320Turbo Multiport Board #1addr(XXX): CPU/Basic module download

Strany 12 - Features

TroubleshootingIntellio C320Turbo User's Manual 6-7Windows 95/98 This section is specific for troubleshooting under Windows 95/98. For generalp

Strany 13 - Check List

IntroductionIntellio C320Turbo User's Manual 1-334567813456781Extensive ModuleBasic ModuleUARTModuleCPUModuleUARTModuleC320 TurboDB25 to DB25 Ca

Strany 14 - Installation Guide

6-8 Intellio C320Turbo User's Manual This indicates MOXA board is found but the IRQ is conflicting with otheradapter. Make sure there is no con

Strany 15 - Hardware Installation

TroubleshootingIntellio C320Turbo User's Manual 6-9appear: “Time out table overflow”, “File table overflow”, “Region table overflow”.The above e

Strany 16

6-10 Intellio C320Turbo User's Manual

Strany 17

Intellio C320Turbo User's Manual A-1AAppppeennddiixxA Technical ReferenceSpecifications Systemv Up to 32 serial ports per Control Boardv Up t

Strany 18 - 25-signal-pin

A-2 Intellio C320Turbo User's Manual CPU Module and UART Module for Desktop Option CPU Module (for Desktop option)v TMS320C52 processorv

Strany 19

Technical ReferenceIntellio C320Turbo User's Manual A-3 UART Module (for Desktop option)v RS-232/RS-422 serial portsv 16550C UART chip with 32

Strany 20

A-4 Intellio C320Turbo User's ManualBasic Module ( Front View ) Multiport ControllerB? a? s?i ?c M?o?d?u?l ?ePower TxD RxD DTR DSR RTS

Strany 21

Technical ReferenceIntellio C320Turbo User's Manual A-5Dual-Ported RAMThere is 512 KB of dual-ported DRAM on the Intellio C320Turbo Control Boar

Strany 22 - L-type Plate

A-6 Intellio C320Turbo User's ManualSW1 Dip switch settings1 2 3 4 5 6 Base AddressON OFF ON OFF ON ON 4C8000OFF OFF ON OFF ON ON 4CC000ON ON OF

Strany 23 - Operating LED Indicators

Technical ReferenceIntellio C320Turbo User's Manual A-7The 16550C is an advanced asynchronous controller capable of on-chip hardwareflow control

Strany 24 - Basic Module

1-4 Intellio C320Turbo User's Manual(API-232). Users can use this library to develop your own applications using VisualC++, Visual Basic, Borlan

Strany 25 - Mix of Various UART Modules

Problem Report FormIntellio C320 Turbo Customer name: Company: Tel: Fax: Email: Date:1. Moxa Product: □ C320 Turbo Serial Number:___________2. Moxa

Strany 26

Technical ReferenceIntellio C320Turbo User's Manual 9

Strany 27 - Software Installation

RETURN PROCEDUREFor product repair, exchange or refund, the customer must:v Provide evidence of original purchase v Obtain a Product Return Agreemen

Strany 28 - Installing Driver

IntroductionIntellio C320Turbo User's Manual 1-5 Windows 3.x, Linux, OS/2 and QNX.v Friendly user interface for configuratio

Strany 29

1-6 Intellio C320Turbo User's ManualInstallation GuideThis section gives a brief summary of how to install the Intellio C320Turbo under eachsupp

Strany 30

Intellio C320Turbo User's Manual 2-122 2 Hardware InstallationThe installation of Intellio C320Turbo consists of hardware installation andsoftw

Strany 31

2-2 Intellio C320Turbo User's Manual JP1 (ON: install jumper) (*: default)1 2 3 4 5 6 7 8 9 IRQON OFF OFF OFF OFF OFF OFF OFF OFF 2OFF ON OFF

Strany 32

Hardware InstallationIntellio C320Turbo User's Manual 2-3slot.Step 7: Fasten the holding screw to make the Control Board fixed.Step 8: Replace t

Strany 33 - Configuring Board and Port

2-4 Intellio C320Turbo User's ManualA: Set the CPU Module power switch to the OFF position. This is absolutelynecessary when installing or remo

Strany 34

Hardware InstallationIntellio C320Turbo User's Manual 2-5C320Turbo Control Board.10-signal-pinCable234567812345678100Power AdapterUART ModuleUAR

Strany 36

2-6 Intellio C320Turbo User's ManualStep 10: Connect the first UART Module to the CPU Module. Connect the secondUART Module to the first one if

Strany 37

Hardware InstallationIntellio C320Turbo User's Manual 2-725-singal-pinCableExtensive ModuleC320 Turbo Control BoardBasic ModuleA: Set the Basic

Strany 38

2-8 Intellio C320Turbo User's ManualControl Board.C: Plug the other DB25 female end into the Basic Module's DB25 connector.Warning! Do not

Strany 39

Hardware InstallationIntellio C320Turbo User's Manual 2-9l Now the installation of the external Basic/Extensive module is complete.Continue to i

Strany 40 -

2-10 Intellio C320Turbo User's ManualBasic ModuleThe left digit shows the number of 8-port unit that configured (if continuous 8 portsare consid

Strany 41

Hardware InstallationIntellio C320Turbo User's Manual 2-11Mix of Various UART ModulesUART Modules with various functions are produced for differ

Strany 42

2-12 Intellio C320Turbo User's Manual

Strany 43

Intellio C320Turbo User's Manual 3-133 3 Software InstallationIn this chapter, software driver installation, configuration and driver upgrade/re

Strany 44 - SCO UNIX, OpenServer or XENIX

3-2 Intellio C320Turbo User's ManualInstalling DriverThe following is the procedure for installing the Intellio C320Turbo driver for the firstti

Strany 45

Software InstallationIntellio C320Turbo User's Manual 3-35. Select “MOXA Intellio Family Multiport Board” in the “Select OEM Option”dialog box

Strany 46

Intellio C320Turbo User's ManualThe software described in this manual is furnished under a license agreement and may be used only inaccordance wi

Strany 47

3-4 Intellio C320Turbo User's Manual7. In the “Property” dialog box, click [Port Setting] to enter the “Individual PortSetting” dialog box to c

Strany 48 - Basic Configuration

Software InstallationIntellio C320Turbo User's Manual 3-5l Non-sequential Port Mapping: (Disable “Auto Enumerating COM number”)Specify the COM

Strany 49 - Non-Modem and Modem Baud Rate

3-6 Intellio C320Turbo User's Manuall Transmission ModeHi-Performance Mode: This feature is set to “Hi-Performance” by default,which accelerate

Strany 50 - Baud Rate Mapping

Software InstallationIntellio C320Turbo User's Manual 3-7Note ! Please double check if all the Intellio C320Turbo components: ControlBoard, lin

Strany 51 - Response

3-8 Intellio C320Turbo User's Manual1. Open [Control Panel], click [Network] icon and select [Adapters] tab.2. Select “MOXA Intellio Family Adap

Strany 52 - Board Reset

Software InstallationIntellio C320Turbo User's Manual 3-9In this configuration panel, you may:l Click [Property] to enter “Property” dialog box

Strany 53

3-10 Intellio C320Turbo User's ManualWindows 95/98Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fullyintegrate the adv

Strany 54 - Driver Removal

Software InstallationIntellio C320Turbo User's Manual 3-11In this configuration panel, you may:l Click on [Add] button to add one more board th

Strany 55 - Driver Installation

3-12 Intellio C320Turbo User's ManualIn the “Property” dialog, you may click on [Port Setting] button to pop up thefollowing “Individual Port

Strany 56

Software InstallationIntellio C320Turbo User's Manual 3-13In the “Individual Port Setting” dialog, you may have two ways to map thephysical por

Strany 57 - Driver Setup

MOXA Internet ServicesCustomer’s satisfaction is always our number one concern. To ensure that customers get the full benefitof our services, Moxa Int

Strany 58

3-14 Intellio C320Turbo User's ManualIn the “Advanced Settings” dialog, you may customize the driver with thefollowing two features:l UART FIF

Strany 59

Software InstallationIntellio C320Turbo User's Manual 3-15Note ! The latest configuration will not take effect unless the system restarts.Note !

Strany 60

3-16 Intellio C320Turbo User's ManualUpdating DriverOpen [Control Panel] icon, and click on [System] icon, and select [Device Manager]tab. Then

Strany 61 - Driver Unloading

Software InstallationIntellio C320Turbo User's Manual 3-17UNIXThere are various UNIX operating systems, such as SCO UNIX, UNIX SVR4.2, andSolari

Strany 62 - MOXA Serial Port Names

3-18 Intellio C320Turbo User's ManualFollow the instructions prompted to finish the driver installationCopyright (C) 1999 Moxa Technologies Co.,

Strany 63 - Windows 3.x

Software InstallationIntellio C320Turbo User's Manual 3-19Then you will be prompted to shutdown the system on your own forkernel rebuilding and

Strany 64 - Configuration

3-20 Intellio C320Turbo User's ManualMOXA TTY Device Naming ConventionIf the Intellio C320Turbo is successfully configured, there will be two

Strany 65 - Utilities

Software InstallationIntellio C320Turbo User's Manual 3-21Taking 8 port Intellio C320Turbo as an example,Administration Utility “mxadm”You can u

Strany 66

3-22 Intellio C320Turbo User's ManualBasic ConfigurationThis is to provide basic settings for driver configuration and features.1. In the “Basic

Strany 67

Software InstallationIntellio C320Turbo User's Manual 3-232. Press PageDown to enter “getty Setting” sub-dialog, there are some noticeablefields

Strany 68

About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog

Strany 69 - 4 Serial Programming Tools

3-24 Intellio C320Turbo User's ManualAdvanced ConfigurationThis is to provide advanced settings for advanced driver features beyond basicsetting

Strany 70 - PComm Programming Library

Software InstallationIntellio C320Turbo User's Manual 3-252. Press PageDown to enter “Advanced Port Settings” sub-dialog, there are somenoticeab

Strany 71 - Serial Programming Tools

3-26 Intellio C320Turbo User's ManualThree levels, Slow, Normal and Fast, of port response time are designed for user'sneed. Ports with fas

Strany 72 - Terminal Emulator

Software InstallationIntellio C320Turbo User's Manual 3-27The board reset utility eliminates the need to shut down the UNIX system to re-initial

Strany 73 - Programming the MOXA Ports

3-28 Intellio C320Turbo User's ManualDriver RemovalIf you want to remove the Intellio C320Turbo device driver and return to yourprevious system

Strany 74 - 2. MOBUFED

Software InstallationIntellio C320Turbo User's Manual 3-29DOSWith over ten years of professional expertise in serial communications, Moxaprovide

Strany 75 - 4. MTCDTR

3-30 Intellio C320Turbo User's ManualAfter installation is complete, you will be prompted to proceed running setupprogram. It is strongly recomm

Strany 76 - 5. MLOWATER

Software InstallationIntellio C320Turbo User's Manual 3-31Driver SetupThe following are steps for configuring the Intellio C320Turbo boards and

Strany 77 - 6. MSTATUS

3-32 Intellio C320Turbo User's Manual2. First, press Enter on the board type field to specify the board type,C320Turbo.3. Now the default base

Strany 78 - 7. MHWFLOW

Software InstallationIntellio C320Turbo User's Manual 3-33LegendBoard Type: Choose the board type, C320Turbo.Ports: The number of ports for C320

Strany 79

Table of ContentsIntroduction ...1-1Overview ...

Strany 80

3-34 Intellio C320Turbo User's ManualLegend: Some noticeable fields and functions are explained below.On board TxD buf: The transmit (output) bu

Strany 81

Software InstallationIntellio C320Turbo User's Manual 3-35Driver LoadingHaving completed the setup, you can load the driver, “BIN\MX-DRV.EXE”,

Strany 82

3-36 Intellio C320Turbo User's ManualMOXA Serial Port NamesEach MOXA serial port is referenced as port number in terms of programming. Theport n

Strany 83 - DOS API-232 Library

Software InstallationIntellio C320Turbo User's Manual 3-37Windows 3.xFor users who need to implement an industrial control system or data acquis

Strany 84 - Diagnose

3-38 Intellio C320Turbo User's Manual MOXA Windows-compatible COMM DriverDue to the limitations of Windows 3.x operating system itself, only up

Strany 85

Software InstallationIntellio C320Turbo User's Manual 3-39UtilitiesThe utility, TTY, is included to help users monitor and debug RS-232communic

Strany 86

3-40 Intellio C320Turbo User's Manualstandard might not be able to operate MOXA COM ports. For instance, LapLink forWindows accesses I/O address

Strany 87

Software InstallationIntellio C320Turbo User's Manual 3-41MOXA Windows API-232 ProgrammingMOXA API-232 Library is available for programming unde

Strany 88 - Connector Connector

3-42 Intellio C320Turbo User's ManualVisual Basic are supported in the driver file directory after driver installation.In addition, for Windows

Strany 89

Intellio C320Turbo User's Manual 4-1 44 4 Serial Programming ToolsMoxa supports powerful but easy se

Strany 90 - C32071T DCE Device

Windows 3.x ...3-37Installing Driver...

Strany 91

4-2 Intellio C320Turbo User's ManualPComm Programming LibraryThe serial communication library is to assist you to develop programs for serialcom

Strany 92 - C32047T DTE Device

Serial Programming ToolsIntellio C320Turbo User's Manual 4-3Monitor (for MOXA boards under Windows NT Only)A useful port status monitoring progr

Strany 93

4-4 Intellio C320Turbo User's ManualTerminal EmulatorThe Terminal Emulator features multi-windows and supports terminal types of VT100and ANSI.

Strany 94

Serial Programming ToolsIntellio C320Turbo User's Manual 4-5UNIXProgramming the MOXA PortsThe system calls that apply to standard tty port also

Strany 95 - RS-422 Impedance Matching

4-6 Intellio C320Turbo User's Manual1. MIBUFEDThis function let you know how many bytes queued in input buffer when thisfunction is issued.Synta

Strany 96 - RJ45 JACK

Serial Programming ToolsIntellio C320Turbo User's Manual 4-7#include <sys/sysmacros.h>#define MOBUFED 0x402struct strioctl ioc;int count;

Strany 97

4-8 Intellio C320Turbo User's ManualThis function, only valid when hardware flow control is turned off (seeMHWFLOW), is used to turn DTR on or o

Strany 98 - C3208xT DCE Device

Serial Programming ToolsIntellio C320Turbo User's Manual 4-9of the output buffer. Each port's output buffer depends on the number of total

Strany 99 - C3208xT DTE Device

4-10 Intellio C320Turbo User's Manual#define MSTATUS 0x407#include <sys/stropts.h>#include <sys/sysmacros.h>struct strioctl ioc;int

Strany 100 - C32020T Link Cable

Serial Programming ToolsIntellio C320Turbo User's Manual 4-11#define CTSFlowControlBitOn 0x01#define RTSFlowControlBitOn 0x02#define HWFlowContr

Strany 102

4-12 Intellio C320Turbo User's ManualUtilitiesYou can use the administration utility, mxadm, to monitor port activity and to doterminal emulati

Strany 103 - Troubleshooting

Serial Programming ToolsIntellio C320Turbo User's Manual 4-13Press Enter on the port, that the cursor stays, to view the port’s communicationpar

Strany 104

4-14 Intellio C320Turbo User's Manual1. Select and Press Enter on item “Communication Setup” to setup up all thecommunication parameters for c

Strany 105

Serial Programming ToolsIntellio C320Turbo User's Manual 4-15DOSInstallationAPI-232 Library is the professional serial programming tool for DOS.

Strany 106

4-16 Intellio C320Turbo User's ManualThere are three major functions in Data Scope utility:1. The Data Scope utility offers transparent monitori

Strany 107 - Windows NT

Serial Programming ToolsIntellio C320Turbo User's Manual 4-17Before executing it, please remove the Moxa driver in advance via executing “Mx-drv

Strany 109 - Windows 95/98

Intellio C320Turbo User's Manual 5-155 5 Connection Option and Cable WiringIn data communications, the term DTE is Data Terminal Equipment like

Strany 110

5-2 Intellio C320Turbo User's ManualUART Module C32045T/71TDB25 Female Connector2 RxD3 TxD4 CTS5 RTS6 DTR7 GND8 DCD20 DSRUART Module C32047TDB25

Strany 111

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-3PC COM2 port, Serial Printer,Terminal, or any DTE DeviceC32047TNull Modem

Strany 112

Intellio C320Turbo User's Manual 1-111 1 IntroductionThis manual covers both the hardware and software installation and configuration ofC320Turb

Strany 113 - Technical Reference

5-4 Intellio C320Turbo User's ManualType 2: Connecting UART Module to a DCE device.Modem,or any DCE DeviceC32045T/71TNull Modem CableC32045T/71T

Strany 114 - Module Side View

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-5Type 3: Connecting UART Module to a DTE device with 3-pin wiring.If the “H

Strany 115

5-6 Intellio C320Turbo User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceC32047TC32047T DTE DeviceDB25 Male Cable Wiring DB9

Strany 116

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-7RS-422 Cable Wiring for C32061T/C32065TThe following RS-422 UART Modules a

Strany 117 - Dual-Ported RAM

5-8 Intellio C320Turbo User's ManualThe followings are operation modes for RS-422:RS-422 Point-to-point RS-422 BroadcastingC32061T/65T RS-422 De

Strany 118

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-9RS-422 Impedance MatchingWhen an electrical signal travels through two dif

Strany 119

5-10 Intellio C320Turbo User's ManualRS-232 Cable Wiring for C32080T/81T/82T/83T &CN20040For Basic/Extensive Modules, only RS-232 interf

Strany 120 - Problem Report Form

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-11Type 1: Connecting Basic/Extensive Module to a DTE device.PC COM2 port, S

Strany 121

5-12 Intellio C320Turbo User's ManualType 2: Connecting Basic/Extensive Module to a DCE device.Modem,or any DCE DeviceC3208xTCable CN20040RJ45 P

Strany 122 - RETURN PROCEDURE

Connection Option and Cable WiringIntellio C320Turbo User's Manual 5-13Type 3: Connecting Basic/Extensive Module to a DTE device with 3-pin wiri

Komentáře k této Příručce

Žádné komentáře