5-10 Intellio C320Turbo User's Manual
RS-232 Cable Wiring for C32080T/81T/82T/83T &
CN20040
For Basic/Extensive Modules, only RS-232 interface with RJ-45 female connector is
supported. A 1.5-meter male RJ-45 to male DB25 RS-232 testing cable, CN20040, is
provided with shipment of the Basic Module.
The following RS-232 Basic Modules are designed for Intellio C320Turbo.
C32080T : Basic Module providing 8 female RS-232 ports.
C32081T : Basic Module providing 16 female RS-232 ports.
The following RS-232 Extensive Modules are designed for Intellio C320Turbo.
C32082T : Extensive Module providing 8 female RS-232 ports.
C32083T : Extensive Module providing 16 female RS-232 ports.
C32080T/81T/82T/83T RJ-45 Jack
Pin Signals
1 DCD
2 DSR
3 RTS
4 GND
5 TxD
6 RxD
7 GND
8 CTS
9 DTR
10 -
1 10