Industio
IndustioIndustio
Industio CP-132U Series
Users Manual
Industrial 2-Port RS-422/485 Serial Board for PCI Bus
First Edition, January 2003
This manual is also available on CD-ROM and at Moxa’s Website
Moxa Technologies Co., Ltd.
Tel: +866-2-8919-1230
Fax: +886-2-8919-1231
www.moxa.com
support@moxa.com.tw
Zobrazit stránku 0
1 2 3 4 5 6 ... 78 79

Shrnutí obsahu

Strany 1 - Industio CP-132U Series

IndustioIndustioIndustioIndustio CP-132U Series User’s Manual Industrial 2-Port RS-422/485 Serial Board for PCI Bus First Edition, January 2003 This

Strany 3 - MOXA Internet Services

22222222 2 Hardware Installation You will need to install both hardware and software for Industio CP-132U Series boards. The hardware install

Strany 4 - Table of Contents

Industio CP-132 Series User’s Manual 2-2CP-132U Series Block Diagram Industio CP-132U Series boards’ hardware configuration for IRQ number and I/O ad

Strany 5 - 1 Introduction

Hardware Installation Industio CP-132 Series User’s Manual 2-3Industio CP-132U Series boards have four onboard DIP Switches, referred to below as S

Strany 6 - Overview

Industio CP-132 Series User’s Manual 2-4 Port 1 DIP Switch Settings S1-1 S2-1 RS-422 — OFF RS-485 (2-wire) ON ON RS-485 (4-wire) OFF ON Port 2

Strany 7 -  Factory automation

Hardware Installation Industio CP-132 Series User’s Manual 2-5Installing the IndustioIndustioIndustioIndustio CP-132U Series Board Step 1: Power o

Strany 9 - Package Checklist

33333333 3 Software Installation In this chapter, the software driver installation, configuration, and driver update/removal procedures are d

Strany 10

Industio CP-132 Series User’s Manual 3-2Windows NT Windows NT supports up to 256 serial ports, from COM1 to COM256. To fully integrate the advanced f

Strany 11 - 2 Hardware Installation

Software Installation Industio CP-132 Series User’s Manual 3-3Installing the Driver The following procedure is for installing the Industio CP-132U

Strany 12 - CP-132U Series Block Diagram

IndustioIndustioIndustioIndustio CP-132U Series User’s Manual The software described in this manual is furnished under a license agreement and may be

Strany 13 - Hardware Installation

Industio CP-132 Series User’s Manual 3-45. Select “MOXA SmartioSmartioSmartioSmartio/IndustioIndustioIndustioIndustio Family multiport board” from th

Strany 14

Software Installation Industio CP-132 Series User’s Manual 3-58. The [Port #] window will open to allow you to change settings, as described below,

Strany 15 - Installing the Industio

Industio CP-132 Series User’s Manual 3-69. Click [OK] in the “Port #” and “Property” dialog boxes to go back to the “MOXA Smartio/Industio Configurat

Strany 16

Software Installation Industio CP-132 Series User’s Manual 3-7  If an error message similar to “Cannot find any configured MOXA CP-132 board!” ap

Strany 17 - 3 Software Installation

Industio CP-132 Series User’s Manual 3-8Driver,” for more details. You may use this configuration panel to:  Click on [Property] to enter the “P

Strany 18 - Windows NT

Software Installation Industio CP-132 Series User’s Manual 3-9Removing the Driver To remove the driver for the Industio CP-132U Series board, 1. O

Strany 19 - Installing the Driver

Industio CP-132 Series User’s Manual 3-10 Install the Smartio PCI board in the system. Start Windows 95/98 to detect the board. Dri

Strany 20

Software Installation Industio CP-132 Series User’s Manual 3-11 First Time Driver Installation Stage This stage presents the steps for installing t

Strany 21 - Software Installation

Industio CP-132 Series User’s Manual 3-12 Windows 95 Windows 98 3. Type A:\Windows.95 in the Location field, and then click [OK] in the [Select Ot

Strany 22

Software Installation Industio CP-132 Series User’s Manual 3-13 Windows 95 Windows 98 5. Type A:\Windows.95 and then click [OK]. The system wil

Strany 23

MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa I

Strany 24 - Updating the Driver

Industio CP-132 Series User’s Manual 3-14 Port Configuration Stage This stage presents the steps for configuring the Industio CP-132U Series board’s

Strany 25 - Windows 95/98

Software Installation Industio CP-132 Series User’s Manual 3-15defined Rx FIFO Trigger to all ports. 7. Select a Tx FIFO Size from the Tx FIFO Siz

Strany 26

Industio CP-132 Series User’s Manual 3-16 Board and Port Ready Stage The Board and Port Ready Stages for Windows 95 and Windows 98 are slightly diffe

Strany 27

Software Installation Industio CP-132 Series User’s Manual 3-17Configuring the Board and Ports Follow the procedure given below if you would like t

Strany 28

Industio CP-132 Series User’s Manual 3-18 Note! Step 5 is optional if you want to assign COM numbers to the Port manually. 5. Check the [Auto En

Strany 29

Software Installation Industio CP-132 Series User’s Manual 3-19 8. Click the [OK] button in the Port X dialog box. 9. Click the [OK] button in th

Strany 30 - Port Configuration Stage

Industio CP-132 Series User’s Manual 3-20 3. Select the [Driver] tab. 4. Click on the [Update Driver...] button. 5. Click on the [Specify a locat

Strany 31

Software Installation Industio CP-132 Series User’s Manual 3-21Removing the Driver This section explains how to remove the Industio CP-132U Series

Strany 32 - Board and Port Ready Stage

Industio CP-132 Series User’s Manual 3-22 Windows 2000/XP Windows 2000/XP supports up to 256 serial ports, from COM1 to COM256. To fully utilize Wind

Strany 33

Software Installation Industio CP-132 Series User’s Manual 3-233. Select Search for a suitable driver… and then click on Next to continue. 4. Sele

Strany 34

Table of Contents Chapter 1 Introduction... 1-1 Overview ...

Strany 35

Industio CP-132 Series User’s Manual 3-24 5. Insert the Moxa Driver CD into the CD-ROM drive, and then specify the location of the file as F:/multi_

Strany 36

Software Installation Industio CP-132 Series User’s Manual 3-25 8. The next window shows the model number of the board, and indicates that Window

Strany 37 - Removing the Driver

Industio CP-132 Series User’s Manual 3-26 10. Click on Next to continue. 11. Select Search for a suitable driver for my device [recommended], an

Strany 38 - Windows 2000/XP

Software Installation Industio CP-132 Series User’s Manual 3-2712. Select Specify a location and then click on Next to continue. 13. Insert the Mo

Strany 39

Industio CP-132 Series User’s Manual 3-28 14. Click on Next to continue with the installation. 15. After all files have been copied to the system,

Strany 40

Software Installation Industio CP-132 Series User’s Manual 3-29How to Check the Installation There are three ways to check the installation of the

Strany 41

Industio CP-132 Series User’s Manual 3-30 If the driver installation was successful, you will be able to see the model number of the CP-132 board lis

Strany 42

Software Installation Industio CP-132 Series User’s Manual 3-31Removing the Driver 1. You can uninstall the board by selecting Start  Settings 

Strany 43

Industio CP-132 Series User’s Manual 3-32 2. Select the Hardware tab, and then click on Device Manager. Use the mouse to place the cursor over the CP

Strany 44

Software Installation Industio CP-132 Series User’s Manual 3-334. The Device Manager window will automatically refresh to show that the driver and

Strany 45 - Device Manager

11111111 1 Introduction Welcome to the MOXA CP-132U Series of industrial 2-port RS-422/485 serial boards for the PCI bus. The following topic

Strany 46 - Event Log

Industio CP-132 Series User’s Manual 3-34 Linux NOTE: This section applies to Linux kernel 2.2.14 or later. The Moxa Smartio/Industio driver is inclu

Strany 47

Software Installation Industio CP-132 Series User’s Manual 3-35msdiag Diagnostic program for displaying installed Moxa Smartio/Industio boards. ms

Strany 48

Industio CP-132 Series User’s Manual 3-36 Smartio/Industio PCI Family multiport boards can be installed together on the same system, and it’s quite p

Strany 49

Software Installation Industio CP-132 Series User’s Manual 3-37Board sequence This driver will activate ISA boards according to the parameter set i

Strany 50 - Introduction

Industio CP-132 Series User’s Manual 3-38 # make clean; make install The driver files "mxser.o" and utilities will be properly compiled and

Strany 51 - Installation

Software Installation Industio CP-132 Series User’s Manual 3-39# ln -s linux-2.4 linux 2. Create link # cd /usr/src/linux/drivers/char # ln -s /mo

Strany 52 - Device naming convention

Industio CP-132 Series User’s Manual 3-40 Static driver configuration (for Linux kernel 2.0.3x, and 2.2.14 or earlier) 1. Create link # cd /usr/src/l

Strany 53 - Module driver configuration

Software Installation Industio CP-132 Series User’s Manual 3-41Note that if the result of "make bzImage" is ERROR, then you must go back

Strany 54 - Static driver configuration

Industio CP-132 Series User’s Manual 3-42 #define MXSERCUMAJOR 45 4. Run "make clean; make install" from /moxa/mxser/driver. Verifying

Strany 55

Software Installation Industio CP-132 Series User’s Manual 3-43Setserial Supported Setserial parameters are listed as below. uart set UART typ

Strany 56

Industio CP-132 Series User’s Manual 1-2Overview Industio—The Industrial Multiport Async Solution Moxa IndustioIndustioIndustioIndustio products are

Strany 57 - Custom configuration

Industio CP-132 Series User’s Manual 3-44 equal to zero) for one Moxa board. Error msg: No interrupt vector can be set for the Moxa ISA board (CAP=x

Strany 58 - Utilities

44444444 4 Serial Programming Tools Moxa supports an easy to use yet powerful serial programming library and communication troubleshooting u

Strany 59 - Troubleshooting

Industio CP-132 Series User’s Manual 4-2PCommPCommPCommPComm Installation To install PCommPCommPCommPComm, run \Setup.exe from the diskette. Note tha

Strany 60

Serial Programming Tools Industio CP-132 Series User’s Manual 4-3that you configure your Industio CP-132U Series ports as described below. There ar

Strany 62

55555555 5 Connection Cables and Cable Wiring In serial data communications, the term DTE stands for Data Terminal Equipment, such as a PC’s

Strany 63 - Serial Programming Tools

Industio CP-132 Series User’s Manual 5-2RS-422/485 Pinouts and Cable Wiring RS-422 Interface The RS-422 standard uses a balanced voltage digital inte

Strany 64

Connection Cables and Cable Wiring Industio CP-132 Series User’s Manual 5-3Pinouts RS-422/485 pinouts for IndustioIndustioIndustioIndustio CP-132U

Strany 65 - Cable Wiring

Industio CP-132 Series User’s Manual 5-4RS-422 pinouts for IndustioIndustioIndustioIndustio CP-132U Series CP-132U (RS-422) 1 TxD-(A) 2 TxD+(B) 3 RxD

Strany 66 - RS-485 Interface

Connection Cables and Cable Wiring Industio CP-132 Series User’s Manual 5-5Cable Wiring RS-422 Point-to-point RS-422 Broadcasting CP-132U R

Strany 67 - Pinouts

Introduction Industio CP-132 Series User’s Manual 1-3Universal PCI The 32/64-bit PCI local bus specification specifies both 3.3V and 5V connector ty

Strany 68

Industio CP-132 Series User’s Manual 5-6Multidrop 2-wire RS-485 (half-duplex) CP-132U RS-485 Device 1 Master Slave 2 Data+ Data+ 1 Data- Data- 5 G

Strany 69

Connection Cables and Cable Wiring Industio CP-132 Series User’s Manual 5-7Impedance Matching and Termination Resistors When using RS-422/485 seria

Strany 71

66666666 6 Troubleshooting Common Industio CP-132U Series problems and possible solutions are listed below. If you still have problems, cont

Strany 72

Industio CP-132 Series User’s Manual 6-22. The MOXA board and driver are activated but cannot transfer (transmit/receive) data. Hardware Causes and

Strany 73 - 6 Troubleshooting

Troubleshooting Industio CP-132 Series User’s Manual 6-3Windows NT This section is specific for troubleshooting under Windows NT. For general probl

Strany 74

Industio CP-132 Series User’s Manual 6-4Windows 95/98 This section is specific for troubleshooting under Windows 95/98. For general problems and solu

Strany 75

AAAAAAAA A Technical ReferenceTechnical ReferenceTechnical ReferenceTechnical Reference Specifications Bus interface 32-bit PCI Number

Strany 76

MOXA EtherDevice Server User’s Manual A-2 Power requirement CP-132 420 mA max. (+5V) CP-132I 700 mA max. (+5V) CP-132IS 710 mA max. (+5V) Dim

Strany 77 - Technical Reference

Return Procedure For product repair, exchange, or refund, the customer must:  Provide evidence of original purchase.  Obtain a Product Return Agr

Strany 78

Industio CP-132 Series User’s Manual 1-4Features The Industio CP-132U Series includes the following products: CP-132UI 2 RS-422/485 ports, Universa

Strany 79 - Return Procedure

Introduction Industio CP-132 Series User’s Manual 1-5Package Checklist You should find the following items in the Industio CP-132U Series package:

Komentáře k této Příručce