Moxa Technologies Industio CP-114 Series CP-114 Series Uživatelský manuál Strana 34

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 79
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 33
Industio CP-132 Series User’s Manual
3-18
Note! Step 5 is optional if you want to assign COM numbers to the Port manually.
5. Check the [Auto Enumerating COM Name] check-box to assign continuous COM
numbers for subsequent ports. For example, if COM 3 is assigned to Port 1, then COM
4 will be automatically assigned to Port 2.
Note! Steps 6 and 7 are optional if the system does not require special
performance tuning.
6. Re-assign the Rx FIFO Trigger by selecting a number from the pull-down list. Check
the [Set the change to all ports] check-box if you want to apply this setting to all
ports.
Rx FIFO trigger levels from 1 to 56 bytes are available, with the default value set at 56
bytes.
7. Re-assign the Tx FIFO Size by selecting a number from the pull-down list. Check the
[Set the change to all ports] check-box if you want to apply this setting to all ports.
Tx FIFO sizes from 1 to 64 bytes are available, with default value set at 64 bytes.
Zobrazit stránku 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 78 79

Komentáře k této Příručce

Žádné komentáře