Industio CP-132 Series User’s Manual
2-3
Industio CP-132U Series boards have four onboard DIP Switches, referred to below as
S1-1, S1-2, S2-1, and S2-2, that allow the user to choose one of three serial
interfaces—RS-422, RS-485 (2-wire), RS-485 (4-wire)—for each of the two ports. Note
that S2-1 and S2-2 select between RS-422 and RS-485, and S1-1 and S1-2 select between
2-wire and 4-wire RS-485 (S1 is only active when S2 is set to ON).